You have performed a firmware update for the selected device using the micro SD card.
10.5
Restoring factory setting
Effects of the factory setting
The following devices can be reset to the factory setting:
• 3RW55 or 3RW55 Failsafe soft starter
– The parameters of the 3RW55 or 3RW55 Failsafe soft starter are reset to the factory
setting.
– User accounts are deleted.
– Ex-relevant parameters are reset.
You will find further information on Ex operation in chapter ATEX / IECEx (Page 206).
• 3RW5 communication module
– The parameters of the 3RW5 communication module are reset.
• 3RW5 HMI High Feature
– The parameters of the 3RW5 HMI High Feature and the PIN for access protection are reset
to the factory setting.
• All devices
– The 3RW55 or 3RW55 Failsafe soft starter, the 3RW5 communication module, and the
3RW5 HMI High Feature are reset to the factory settings, as described above.
Requirements
The control priority lies with the source of the command to restore the factory setting.
DANGER
Restoring the factory setting with active Ex operation.
Will cause death or serious injury.
Restoring the factory setting with active Ex operation (Page 207) is not permissible for all
procedures.
To restore the factory setting with active Ex operation, choose the procedure using the master
RESET key on the 3RW5 HMI High Feature (Page 280).