Circuit diagrams
7.2 Typical circuits
3SK1 safety relays
122
Manual, 04/2013, A5E02526190021A/RS-AA/01
Table 7- 16 Typical circuit 16:
Two-hand operation, with cross-circuit detection, with autostart
•
Autostart
•
With cross-circuit detection
•
2 x single-channel
•
Jumper T1/PAR for NC/NO evaluation
•
Sensor: Two-hand NO/NO sensor
•
3SK112 Advanced
DIP switch
1
2
3
4
OFF
left
ON
right
OFF
left
—
PL in accordance with ISO 13849-1
e
,1
7
3$5
,1 ,1) ,16
7
$
$
,1.
/
4
4Q
$XWRVWDUW0RQLWRUHG6WDUW
&URVVIDXOWGHWHFWLRQ2))21
VLQJOHFKVHQVRUVGRXEOHFKVHQVRU
6WDUWXS7HVW\HVQR
6(75(6(7
4
4Q
0
Safety Integrity Level (SILCL) to IEC
61508
3
For more information on two-hand operation, please refer to the chapter Two-hand