Voltage variant 110 V ... 240 V AC/DC:
Only floating sensors can be connected to the device version 3SK1111-.AW20.
Connection of the two-channel sensor takes place via T1/IN1 and T2/IN2.
5.1.3.6
Outputs
The safety relay has the following outputs:
● Safety-related outputs (enabling circuits, relays), NO contacts: 13/14, 23/24, 33/34
● Non-safety-related outputs (enabling circuit; relays), NC contacts: 41/42
5.1.3.7
Display of the operating state
Display of the operating state
Two LEDs and a slide switch indicate the operating state and functioning of the device:
● DEVICE
● OUT
LED displays
LED
Operation
DEVICE
OUT
Line supply
Sensor
START button
Enabling circuit
Green
Green
Not pressed
Pressed
Closed
Green
OFF
Pressed
Not pressed
Open
Green
OFF
ON
Not pressed
Not pressed
Open
Error
OFF
OFF
Cross-circuit or no power supply
Open
5.1.3.8
Function setting
Setting the functions
Slide switch
AUTO
Autostart
Start
AUTO
MONITORED
MONITORED
Monitored start
In the delivery state, the slide switch is at the bottom (monitored start).
Summary of Contents for SIRIUS 3SK1
Page 2: ......
Page 10: ...Table of contents 3SK1 safety relays 10 Manual 04 2013 A5E02526190021A RS AA 01 ...
Page 186: ...Commissioning 3SK1 safety relays 186 Manual 04 2013 A5E02526190021A RS AA 01 ...
Page 258: ...Accessories 3SK1 safety relays 258 Manual 04 2013 A5E02526190021A RS AA 01 ...
Page 260: ...Appendix A 1 Correction sheet 3SK1 safety relays 260 Manual 04 2013 A5E02526190021A RS AA 01 ...
Page 261: ......