External circuitry
10.2 Typical circuits
3TK2826 safety relay
48
Manual, 08/2007, GWA NEB 926 1579-02 DS 02
Table 10-15 Circuit example 13: NC and NO contacts without cross-circuit detection, with monitored
start
•
Without cross-circuit detection
•
NC c NO contact
•
2-channel
•
Monitored start
•
3TK2826-.BB4.
DIP switch
1
2
3
4
5
6
7
8
0
0
1
—
1
—
—
—
Category in accordance with DIN
EN ISO 13849-1
3
Y12 T1 Y33 T3 1
Y22 T2 Y34
START
9'&
A1
A2
M
K
1
K
n
..
.
Safety Integrity Level (SIL),
in accordance with IEC 61508
2
Table 10-16 Circuit example 14: NC and NO contacts without cross-circuit detection, with autostart
•
Without cross-circuit detection
•
NC c NO contact
•
2-channel
•
Autostart
•
3TK2826-.BB4.
DIP switch
1
2
3
4
5
6
7
8
0
0
1
—
0
0
—
—
Category in accordance with DIN
EN ISO 13849-1
3
Y12
T1
Y33
T3
1
Y22
T2
Y34
9'&
A1
A2
M
K
1
K
n
..
.
Safety Integrity Level (SIL),
in accordance with IEC 61508
2