Configuration
53
Siemens AG
06.2010
2.
Highlight the box beside
Disk Almost Full Notify
, and press the button.
Î
Select the percentage level of disk usage at which you want the DVR to trigger
an alert. Percentage levels range from 80% to 99%.
3.
Highlight the first box beside
Disk S.M.A.R.T.
, and press the button.
4.
Use the Up and Down arrow buttons to scroll through the numbers. Refer to the
hard disk drive manufacturer’s documentation for the correct temperature
setting.
Î
If the temperature of hard disk drive exceeds the defined threshold, the system
triggers an alert.
5.
Highlight the second box beside
Disk S.M.A.R.T.
, and press the button.
6.
Select either
ºC (Celsius)
or
ºF (Fahrenheit)
, and press the button.
7.
Highlight the
Actions
tab and the
System Event Actions
screen displays.
Fig. 47
System Event Actions screen
Actions
The DVR can be set to react to system events. System events can activate the
Alarm-Out connector, sound the DVR’s internal buzzer, and/or notify a number of
different devices.
1.
Highlight the
Alarm-Out
box beside the desired event (Check Recording,
Check Alarm-In, Disk Almost Full, Disk Full, Disk Bad, Disk Temperature, or
Disk S.M.A.R.T.), and press the button.
2.
Select between Alarm Output connector and the DVR’s internal buzzer that you
would like to activate and to sound whenever the DVR detects event.
NOTE
The
Alarm-Out
action cannot be set to System and Panic Record events.
3.
Highlight the
Notify
box beside the desired event (System, Panic Record,
Check Recording, Check Alarm-In, Disk Almost Full, Disk Full, Disk Bad, Disk
Temperature, or Disk S.M.A.R.T.), and press the button.