Parameter path
Description
Type
Hex
Dec
Resolution
FEC920: USER GUIDE
Page 152
September 18
ModbusMaster.25.Data.Set
Sets a digital value (1 = on; 0 = off)
bool
7e13
32275
Not applicable
ModbusMaster.25.Data.SlaveDevice
Slave device to communicate with.
uint8
7b2c
31532
Not applicable
ModbusMaster.25.Data.Status
Transaction status (as for Modbus Master.1
uint8
7cef
31983
Not applicable
ModbusMaster.25.Data.Value
The value to be written to the slave device
float32
7c72
31858
2dp
ModbusMaster.26.Data.AlarmStatus
Alarm status (as for Modbus Master.1)
uint8
7dd4
32212
Not applicable
ModbusMaster.26.Data.BitPosition
Bit position of the bit of interest in a 16 bit data type
uint8
7d68
32104
Not applicable
ModbusMaster.26.Data.ChanAlarmStatus
Channel alarm status (as for Modbus Master.1)
uint8
7df4
32244
Not applicable
ModbusMaster.26.Data.DataType
Type of data being read/written (as for Modbus Master.1)
uint8
7c1f
31775
Not applicable
ModbusMaster.26.Data.Descriptor
Description for this data item
string_t
6894
26772
Not applicable
ModbusMaster.26.Data.Digital
Digital status (0 = Off, 1 = On)
bool
7e34
32308
Not applicable
ModbusMaster.26.Data.FallBackValue
Fall back value to be written to the slave device
float32
7cb0
31920
2dp
ModbusMaster.26.Data.FunctionCode
The Modbus function code (as for Modbus Master.1)
uint8
7c01
31745
Not applicable
ModbusMaster.26.Data.ModbusAddress
Modbus register address of the data to be read/written
float32
7bde
31710
0dp
ModbusMaster.26.Data.Mode
Auto Manual mode selection (0 = Auto; 1 = Manual)
uint8
7db4
32180
Not applicable
ModbusMaster.26.Data.Number
Used for multiple instance parameters
uint8
7d2c
32044
Not applicable
ModbusMaster.26.Data.ParameterList
Parameter list for a specific slave device
uint8
7d0e
32014
Not applicable
ModbusMaster.26.Data.Priority
Read/Write frequency (as for Modbus Master.1)
uint8
7c3d
31805
Not applicable
ModbusMaster.26.Data.PV
Process value received from slave device
float32
7b64
31588
2dp
ModbusMaster.26.Data.Scaling
Scaling in decimal places for non floating point data types
uint8
7d4a
32074
Not applicable
ModbusMaster.26.Data.Send
1 = send the write value to the slave
bool
7cd2
31954
Not applicable
ModbusMaster.26.Data.Set
Sets a digital value (1 = on; 0 = off)
bool
7e14
32276
Not applicable
ModbusMaster.26.Data.SlaveDevice
Slave device to communicate with.
uint8
7b2d
31533
Not applicable
ModbusMaster.26.Data.Status
Transaction status (as for Modbus Master.1
uint8
7cf0
31984
Not applicable
ModbusMaster.26.Data.Value
The value to be written to the slave device
float32
7c74
31860
2dp
ModbusMaster.27.Data.AlarmStatus
Alarm status (as for Modbus Master.1)
uint8
7dd5
32213
Not applicable
ModbusMaster.27.Data.BitPosition
Bit position of the bit of interest in a 16 bit data type
uint8
7d69
32105
Not applicable
ModbusMaster.27.Data.ChanAlarmStatus
Channel alarm status (as for Modbus Master.1)
uint8
7df5
32245
Not applicable
ModbusMaster.27.Data.DataType
Type of data being read/written (as for Modbus Master.1)
uint8
7c20
31776
Not applicable
ModbusMaster.27.Data.Descriptor
Description for this data item
string_t
68a9
26793
Not applicable
ModbusMaster.27.Data.Digital
Digital status (0 = Off, 1 = On)
bool
7e35
32309
Not applicable
ModbusMaster.27.Data.FallBackValue
Fall back value to be written to the slave device
float32
7cb2
31922
2dp
ModbusMaster.27.Data.FunctionCode
The Modbus function code (as for Modbus Master.1)
uint8
7c02
31746
Not applicable
ModbusMaster.27.Data.ModbusAddress
Modbus register address of the data to be read/written
float32
7be0
31712
0dp
ModbusMaster.27.Data.Mode
Auto Manual mode selection (0 = Auto; 1 = Manual)
uint8
7db5
32181
Not applicable
ModbusMaster.27.Data.Number
Used for multiple instance parameters
uint8
7d2d
32045
Not applicable
ModbusMaster.27.Data.ParameterList
Parameter list for a specific slave device
uint8
7d0f
32015
Not applicable
ModbusMaster.27.Data.Priority
Read/Write frequency (as for Modbus Master.1)
uint8
7c3e
31806
Not applicable
ModbusMaster.27.Data.PV
Process value received from slave device
float32
7b66
31590
2dp
ModbusMaster.27.Data.Scaling
Scaling in decimal places for non floating point data types
uint8
7d4b
32075
Not applicable
ModbusMaster.27.Data.Send
1 = send the write value to the slave
bool
7cd3
31955
Not applicable
ModbusMaster.27.Data.Set
Sets a digital value (1 = on; 0 = off)
bool
7e15
32277
Not applicable
ModbusMaster.27.Data.SlaveDevice
Slave device to communicate with.
uint8
7b2e
31534
Not applicable
ModbusMaster.27.Data.Status
Transaction status (as for Modbus Master.1
uint8
7cf1
31985
Not applicable
ModbusMaster.27.Data.Value
The value to be written to the slave device
float32
7c76
31862
2dp
ModbusMaster.28.Data.AlarmStatus
Alarm status (as for Modbus Master.1)
uint8
7dd6
32214
Not applicable
ModbusMaster.28.Data.BitPosition
Bit position of the bit of interest in a 16 bit data type
uint8
7d6a
32106
Not applicable
ModbusMaster.28.Data.ChanAlarmStatus
Channel alarm status (as for Modbus Master.1)
uint8
7df6
32246
Not applicable
ModbusMaster.28.Data.DataType
Type of data being read/written (as for Modbus Master.1)
uint8
7c21
31777
Not applicable
ModbusMaster.28.Data.Descriptor
Description for this data item
string_t
68be
26814
Not applicable
ModbusMaster.28.Data.Digital
Digital status (0 = Off, 1 = On)
bool
7e36
32310
Not applicable
ModbusMaster.28.Data.FallBackValue
Fall back value to be written to the slave device
float32
7cb4
31924
2dp
ModbusMaster.28.Data.FunctionCode
The Modbus function code (as for Modbus Master.1)
uint8
7c03
31747
Not applicable
ModbusMaster.28.Data.ModbusAddress
Modbus register address of the data to be read/written
float32
7be2
31714
0dp
ModbusMaster.28.Data.Mode
Auto Manual mode selection (0 = Auto; 1 = Manual)
uint8
7db6
32182
Not applicable
ModbusMaster.28.Data.Number
Used for multiple instance parameters
uint8
7d2e
32046
Not applicable
ModbusMaster.28.Data.ParameterList
Parameter list for a specific slave device
uint8
7d10
32016
Not applicable
ModbusMaster.28.Data.Priority
Read/Write frequency (as for Modbus Master.1)
uint8
7c3f
31807
Not applicable
ModbusMaster.28.Data.PV
Process value received from slave device
float32
7b68
31592
2dp
ModbusMaster.28.Data.Scaling
Scaling in decimal places for non floating point data types
uint8
7d4c
32076
Not applicable
ModbusMaster.28.Data.Send
1 = send the write value to the slave
bool
7cd4
31956
Not applicable
ModbusMaster.28.Data.Set
Sets a digital value (1 = on; 0 = off)
bool
7e16
32278
Not applicable
ModbusMaster.28.Data.SlaveDevice
Slave device to communicate with.
uint8
7b2f
31535
Not applicable
ModbusMaster.28.Data.Status
Transaction status (as for Modbus Master.1
uint8
7cf2
31986
Not applicable
ModbusMaster.28.Data.Value
The value to be written to the slave device
float32
7c78
31864
2dp
ModbusMaster.29.Data.AlarmStatus
Alarm status (as for Modbus Master.1)
uint8
7dd7
32215
Not applicable
ModbusMaster.29.Data.BitPosition
Bit position of the bit of interest in a 16 bit data type
uint8
7d6b
32107
Not applicable
ModbusMaster.29.Data.ChanAlarmStatus
Channel alarm status (as for Modbus Master.1)
uint8
7df7
32247
Not applicable
ModbusMaster.29.Data.DataType
Type of data being read/written (as for Modbus Master.1)
uint8
7c22
31778
Not applicable
ModbusMaster.29.Data.Descriptor
Description for this data item
string_t
70ff
28927
Not applicable
ModbusMaster.29.Data.Digital
Digital status (0 = Off, 1 = On)
bool
7e37
32311
Not applicable
ModbusMaster.29.Data.FallBackValue
Fall back value to be written to the slave device
float32
7cb6
31926
2dp
ModbusMaster.29.Data.FunctionCode
The Modbus function code (as for Modbus Master.1)
uint8
7c04
31748
Not applicable
ModbusMaster.29.Data.ModbusAddress
Modbus register address of the data to be read/written
float32
7be4
31716
0dp
ModbusMaster.29.Data.Mode
Auto Manual mode selection (0 = Auto; 1 = Manual)
uint8
7db7
32183
Not applicable
ModbusMaster.29.Data.Number
Used for multiple instance parameters
uint8
7d2f
32047
Not applicable
ModbusMaster.29.Data.ParameterList
Parameter list for a specific slave device
uint8
7d11
32017
Not applicable
ModbusMaster.29.Data.Priority
Read/Write frequency (as for Modbus Master.1)
uint8
7c40
31808
Not applicable
A5E45696052A Rev-AA