Parameter path
Description
Type
Hex
Dec
Resolution
FEC920: USER GUIDE
Page 178
September 18
VirtualChannel.27.Main.RolloverValue
Rollover value
float32
2652
9810
Set by VirtualChannel.27.Main.Resolution
VirtualChannel.27.Main.Status
As VirtualChannel1.Main.Status
uint8
0173
371
Not applicable
VirtualChannel.27.Main.TimeRemaining
Time remaining before the calculation is made
time_t
2649
9801
Set by Network.Modbus.TimeFormat
VirtualChannel.27.Main.Trigger
Increment/decrement counter. 0 = No; 1 = Yes
bool
264e
9806
Not applicable
VirtualChannel.27.Main.Type
As VirtualChannel1.Main.Type
uint8
2640
9792
Not applicable
VirtualChannel.27.Main.Units
Units descriptor
string_t
4dd4
19924
Not applicable
VirtualChannel.27.Main.UnitsScaler
Units scaler for totalisers
float32
2643
9795
1dp
VirtualChannel.27.Trend.Colour
As VirtualChannel1.Trend.Colour
uint8
2760
10080
Not applicable
VirtualChannel.27.Trend.SpanHigh
Specifies the highest PV (output value) to be displayed
float32
2762
10082
Same as VirtualChannel.27.Main.PV
VirtualChannel.27.Trend.SpanLow
Specifies the lowest PV (output value) to be displayed
float32
2761
10081
Same as VirtualChannel.27.Main.PV
VirtualChannel.28.Main.Descriptor
Virtual Channel descriptor
string_t
4dda
19930
Not applicable
VirtualChannel.28.Main.Disable
1 = Virtual channel disabled
bool
27a3
10147
Not applicable
VirtualChannel.28.Main.HighCutOff
The highest input value that will be totalised/counted
float32
2685
9861
Set by VirtualChannel.28.Main.Resolution
VirtualChannel.28.Main.Input1
Input 1 value
float32
2687
9863
Set by VirtualChannel.28.Main.Resolution
VirtualChannel.28.Main.Input2
Input 2 value
float32
2688
9864
Set by VirtualChannel.28.Main.Resolution
VirtualChannel.28.Main.LowCutOff
The lowest input value that will be totalised/counted
float32
2684
9860
Set by VirtualChannel.28.Main.Resolution
VirtualChannel.28.Main.ModbusInput
Modbus input value
float32
2686
9862
Set by VirtualChannel.28.Main.Resolution
VirtualChannel.28.Main.Operation
Specifies the operation of the virtual channel
uint8
2681
9857
Not applicable
VirtualChannel.28.Main.Period
The time period over which the calculation is made
int32
268a
9866
Not applicable
VirtualChannel.28.Main.Preset
Initiate preset. 0 = No; 1 = Yes
bool
268c
9868
Not applicable
VirtualChannel.28.Main.PresetValue
Specifies the preset value
float32
268d
9869
Set by VirtualChannel.28.Main.Resolution
VirtualChannel.28.Main.PV
The virtual channel output value
float32
0174
372
Set by VirtualChannel.28.Main.Resolution
VirtualChannel.28.Main.Reset
Initiate reset. 0 = No; 1 = Yes
bool
268b
9867
Not applicable
VirtualChannel.28.Main.Resolution
Specifies the resolution/number of decimal places
uint8
2682
9858
Not applicable
VirtualChannel.28.Main.Rollover
A pulse signal to indicate PV (output) has just rolled over
bool
2691
9873
Not applicable
VirtualChannel.28.Main.RolloverValue
Rollover value
float32
2692
9874
Set by VirtualChannel.28.Main.Resolution
VirtualChannel.28.Main.Status
As VirtualChannel1.Main.Status
uint8
0175
373
Not applicable
VirtualChannel.28.Main.TimeRemaining
Time remaining before the calculation is made
time_t
2689
9865
Set by Network.Modbus.TimeFormat
VirtualChannel.28.Main.Trigger
Increment/decrement counter. 0 = No; 1 = Yes
bool
268e
9870
Not applicable
VirtualChannel.28.Main.Type
As VirtualChannel1.Main.Type
uint8
2680
9856
Not applicable
VirtualChannel.28.Main.Units
Units descriptor
string_t
4def
19951
Not applicable
VirtualChannel.28.Main.UnitsScaler
Units scaler for totalisers
float32
2683
9859
1dp
VirtualChannel.28.Trend.Colour
As VirtualChannel1.Trend.Colour
uint8
27a0
10144
Not applicable
VirtualChannel.28.Trend.SpanHigh
Specifies the highest PV (output value) to be displayed
float32
27a2
10146
Same as VirtualChannel.28.Main.PV
VirtualChannel.28.Trend.SpanLow
Specifies the lowest PV (output value) to be displayed
float32
27a1
10145
Same as VirtualChannel.28.Main.PV
VirtualChannel.29.Main.Descriptor
Virtual Channel descriptor
string_t
4df5
19957
Not applicable
VirtualChannel.29.Main.Disable
1 = Virtual channel disabled
bool
27e3
10211
Not applicable
VirtualChannel.29.Main.HighCutOff
The highest input value that will be totalised/counted
float32
26c5
9925
Set by VirtualChannel.29.Main.Resolution
VirtualChannel.29.Main.Input1
Input 1 value
float32
26c7
9927
Set by VirtualChannel.29.Main.Resolution
VirtualChannel.29.Main.Input2
Input 2 value
float32
26c8
9928
Set by VirtualChannel.29.Main.Resolution
VirtualChannel.29.Main.LowCutOff
The lowest input value that will be totalised/counted
float32
26c4
9924
Set by VirtualChannel.29.Main.Resolution
VirtualChannel.29.Main.ModbusInput
Modbus input value
float32
26c6
9926
Set by VirtualChannel.29.Main.Resolution
VirtualChannel.29.Main.Operation
Specifies the operation of the virtual channel
uint8
26c1
9921
Not applicable
VirtualChannel.29.Main.Period
The time period over which the calculation is made
int32
26ca
9930
Not applicable
VirtualChannel.29.Main.Preset
Initiate preset. 0 = No; 1 = Yes
bool
26cc
9932
Not applicable
VirtualChannel.29.Main.PresetValue
Specifies the preset value
float32
26cd
9933
Set by VirtualChannel.29.Main.Resolution
VirtualChannel.29.Main.PV
The virtual channel output value
float32
0176
374
Set by VirtualChannel.29.Main.Resolution
VirtualChannel.29.Main.Reset
Initiate reset. 0 = No; 1 = Yes
bool
26cb
9931
Not applicable
VirtualChannel.29.Main.Resolution
Specifies the resolution/number of decimal places
uint8
26c2
9922
Not applicable
VirtualChannel.29.Main.Rollover
A pulse signal to indicate PV (output) has just rolled over
bool
26d1
9937
Not applicable
VirtualChannel.29.Main.RolloverValue
Rollover value
float32
26d2
9938
Set by VirtualChannel.29.Main.Resolution
VirtualChannel.29.Main.Status
As VirtualChannel1.Main.Status
uint8
0177
375
Not applicable
VirtualChannel.29.Main.TimeRemaining
Time remaining before the calculation is made
time_t
26c9
9929
Set by Network.Modbus.TimeFormat
VirtualChannel.29.Main.Trigger
Increment/decrement counter. 0 = No; 1 = Yes
bool
26ce
9934
Not applicable
VirtualChannel.29.Main.Type
As VirtualChannel1.Main.Type
uint8
26c0
9920
Not applicable
VirtualChannel.29.Main.Units
Units descriptor
string_t
4e0a
19978
Not applicable
VirtualChannel.29.Main.UnitsScaler
Units scaler for totalisers
float32
26c3
9923
1dp
VirtualChannel.29.Trend.Colour
As VirtualChannel1.Trend.Colour
uint8
27e0
10208
Not applicable
VirtualChannel.29.Trend.SpanHigh
Specifies the highest PV (output value) to be displayed
float32
27e2
10210
Same as VirtualChannel.29.Main.PV
VirtualChannel.29.Trend.SpanLow
Specifies the lowest PV (output value) to be displayed
float32
27e1
10209
Same as VirtualChannel.29.Main.PV
VirtualChannel.30.Main.Descriptor
Virtual Channel descriptor
string_t
4e10
19984
Not applicable
VirtualChannel.30.Main.Disable
1 = Virtual channel disabled
bool
2823
10275
Not applicable
VirtualChannel.30.Main.HighCutOff
The highest input value that will be totalised/counted
float32
2705
9989
Set by VirtualChannel.30.Main.Resolution
VirtualChannel.30.Main.Input1
Input 1 value
float32
2707
9991
Set by VirtualChannel.30.Main.Resolution
VirtualChannel.30.Main.Input2
Input 2 value
float32
2708
9992
Set by VirtualChannel.30.Main.Resolution
VirtualChannel.30.Main.LowCutOff
The lowest input value that will be totalised/counted
float32
2704
9988
Set by VirtualChannel.30.Main.Resolution
VirtualChannel.30.Main.ModbusInput
Modbus input value
float32
2706
9990
Set by VirtualChannel.30.Main.Resolution
VirtualChannel.30.Main.Operation
Specifies the operation of the virtual channel
uint8
2701
9985
Not applicable
VirtualChannel.30.Main.Period
The time period over which the calculation is made
int32
270a
9994
Not applicable
VirtualChannel.30.Main.Preset
Initiate preset. 0 = No; 1 = Yes
bool
270c
9996
Not applicable
VirtualChannel.30.Main.PresetValue
Specifies the preset value
float32
270d
9997
Set by VirtualChannel.30.Main.Resolution
VirtualChannel.30.Main.PV
The virtual channel output value
float32
0178
376
Set by VirtualChannel.30.Main.Resolution
VirtualChannel.30.Main.Reset
Initiate reset. 0 = No; 1 = Yes
bool
270b
9995
Not applicable
VirtualChannel.30.Main.Resolution
Specifies the resolution/number of decimal places
uint8
2702
9986
Not applicable
VirtualChannel.30.Main.Rollover
A pulse signal to indicate PV (output) has just rolled over
bool
2711
10001
Not applicable
VirtualChannel.30.Main.RolloverValue
Rollover value
float32
2712
10002
Set by VirtualChannel.30.Main.Resolution
VirtualChannel.30.Main.Status
As VirtualChannel1.Main.Status
uint8
0179
377
Not applicable
VirtualChannel.30.Main.TimeRemaining
Time remaining before the calculation is made
time_t
2709
9993
Set by Network.Modbus.TimeFormat
A5E45696052A Rev-AA