Technical data
8.4 Outputs
SITRANS LU150
36
Operating Instructions, 03/2016, A5E34590123-AB
8.4
Outputs
mA output
Range
4 to 20 mA
Span
proportional or inversely proportional
Accuracy
0.25% of full scale at reference conditions
Resolution
3 mm (0.125")
Loading
600 ohms max loop load at 24 V DC supply
Cable
twisted pair, AWG 28 to 16 (0.34 to 1.5 mm) or equivalent
8.5
Construction
Combined sensor and electronics package
Sensor housing
material
PVDF
mounting
threaded
•
2" NPT ((Taper), ANSI/ASME B1.20.1)
•
R 2" ((BSPT), EN 10226)
•
G 2" ((BSPP), EN ISO 228-1
•
4" Sanitary
optional flange
adapter
•
2" NPT - 7ML1830-1BT
•
2" BSPT - 7ML1830-1BU
Enclosure material
PBT
Connection
•
1 x M20 or 1/2" NPT conduit entry
•
2 screw terminal block for 2.5 mm
2
•
(14 ga) solid wire / 1.5 mm
2
(16 ga) stranded wire max
Enclosure rating
Type 6/NEMA 6/IP68 (2 meters for 24 hours)
Weight
1.3 kg
8.6
Operating conditions
Location
indoor / outdoor
Ambient temperature
continuous
-30 to +60 °C (-22 to +140 °F)
-20 °C (-5 °F) if metal mounting
Relative humidity
suitable for outdoor (Type 6/NEMA 6/IP68 (2 meters for 24 hours))
Installation category
I
Pollution degree
4
Summary of Contents for SITRANS LU150
Page 1: ...Operating Instructions SITRANS LU150 03 2016 Edition Ultrasonic Transmitters ...
Page 7: ...Introduction SITRANS LU150 6 Operating Instructions 03 2016 A5E34590123 AB ...
Page 9: ...Description SITRANS LU150 8 Operating Instructions 03 2016 A5E34590123 AB ...
Page 39: ...Technical data 8 7 Approvals SITRANS LU150 38 Operating Instructions 03 2016 A5E34590123 AB ...