Technical data
7.12 Trunking units LXC..53 (copper)
SIVACON 8PS - Configuring with LX system
Configuration Manual, 10/2011, A5E02194899-02
147
System-specific data
LXC
0653
0753
0853
0953
Rated current
I
e
A
2500
3200
5)
4000
5000
Conductor impedance
Resistance
R
20
mΩ/m 0.017
0.013
0.011
0.009
Reactance
X
20
mΩ/m 0.009
0.011
0.008
0.005
At 50 Hz and + 20 °C
busbar temperature
Impedance
Z
20
mΩ/m 0.019
0.017
0.014
0.010
Resistance
R
1
mΩ/m 0.021
0.016
0.014
0.011
Reactance
X
1
mΩ/m 0.009
0.011
0.008
0.005
At 50 Hz and final heating
of busbars
Impedance
Z
1
mΩ/m 0.022
0.019
0.016
0.012
Resistance
R
F
mΩ/m 0.087
0.069
0.048
0.029
Reactance
X
F
mΩ/m 0.091
0.075
0.062
0.049
for 5-pole systems (PE)
under fault conditions
acc. to EN 60439-2
Impedance
Z
F
mΩ/m 0.126
0.101
0.078
0.057
Resistance
R
F
mΩ/m 0.069
0.053
0.037
0.021
Reactance
X
F
mΩ/m 0.074
0.063
0.052
0.042
for 5-pole systems (N)
under fault conditions
acc. to EN 60439-2
Impedance
Z
F
mΩ/m 0.101
0.082
0.063
0.046
Zero impedance
R
0
mΩ/m 0.228
0.180
0.122
0.070
X
0
mΩ/m 0.254
0.203
0.170
0.137
for 5-pole systems (PE)
acc. to DIN EN 60909-0 /
VDE 0102
Z
0
mΩ/m 0.342
0.271
0.209
0.154
R
0
mΩ/m 0.137
0.105
0.074
0.043
X
0
mΩ/m 0.100
0.084
0.069
0.053
for 5-pole systems (N)
acc. to DIN EN 60909-0 /
VDE 0102
Z
0
mΩ/m 0.169
0.134
0.101
0.068
Short-circuit rating
Rated short-time
withstand current
rms value t = 1 s
I
cw
kA
86
100
150
150
Rated impulse withstand
current
Peak value
I
pk
kA
189
220
255
255
Conductor material
Copper
No. of busbars
5
5
10
10
L1, L2, L3
A
mm
2
1192
1586
1892
2384
Conductor cross section
N
A
mm
2
1192
1586
1892
2384
PE = enclosure
A
mm
2
1348
1348
2270
2696
Equivalent copper cross
section
+ busbar
A
mm
2
1192
1586
1892
2384
Weights
kg/m
66.3
85.5
107.2
133.2
1)
Reduction in rated current to 800 A with horizontal flat mounting position
2)
Reduction in rated current to 1380 A with horizontal flat mounting position
3)
Reduction in rated current to 1570 A with horizontal flat mounting position
4)
Reduction in rated current to 1900 A with horizontal flat mounting position
5)
Reduction in rated current to 3100 A with horizontal flat mounting position