Scale parameters and functions
8.19 DR 30 current process values
SIWAREX WP231
116
Manual, 07/2014, A5E31238908A-02
8.19.5
Gross / net weight
The current weight for the main display. The resolution corresponds to the scale interval
(Page 69) specified in data record DR 3.
8.19.6
Gross / net weight with increased resolution (x 10)
The current weight for the main display in higher resolution. The resolution corresponds to
the scale interval specified in data record DR 3 x 10.
8.19.7
Tare weight
The current tare weight (scale interval from DR 3). The resolution corresponds to the scale
interval specified in data record DR 3.
8.19.8
Gross process weight (commissioning aid)
The current gross weight. Values are rounded as specified in data record DR 3 with the
"Decimal places for process values" (Page 71) parameter.
8.19.9
Net process weight (commissioning aid)
The current net weight. Values are rounded as specified in data record DR 3 with the
"Decimal places for process values" (Page 71) parameter.
8.19.10
Refresh counter for process values
Measured values are calculated every 10 ms in the SIWAREX module. A counter is
incremented by 1 each time. Once the counter reaches the value 65536, it starts again from
zero. The counter can be used as a time stamp for data record DR 30.
8.19.11
Last report ID
The last generated report ID is displayed.
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...