Scale parameters and functions
8.20 DR 31 advanced current process values
SIWAREX WP231
118
Manual, 07/2014, A5E31238908A-02
Variable
Note
Type
Length
(bytes)
Rw
Default Min.
Max.
Modbus
registers
(Page 120)
Current status of output 0
BIT
0
r
0
0
1
3312.8
Current status of output 1
BIT
0
r
0
0
1
3312.7
Current status of output 2
BIT
0
r
0
0
1
3312.6
Current status of output 3
BIT
0
r
0
0
1
3312.5
Reserve
BIT
0
r
0
0
1
3312.4
Reserve
BIT
0
r
0
0
1
3312.3
Reserve
BIT
0
r
0
0
1
3312.2
Reserve
BIT
2
r
0
0
1
3312.1
(Page 120)
Refresh counter incremented by 1
if weight values were changed
USHORT 2
r
0
-
-
3313
(Page 120)
Currently measured load cell
signal
FLOAT
4
r
0
-
-
3314
8.20.2
Unfiltered digit value
The unfiltered digit value is the internal measured value immediately before filtering.
8.20.3
Filtered digit value
The filtered digit value is the internal measured value immediately after filtering.
8.20.4
Filtered digit value (commissioning aid)
The filtered digit value is the internal measured value immediately after filtering with the
commissioning filter.
8.20.5
Digits for analog output
The current digit value for the digital-to-analog converter for the analog output. The
resolution of the analog output is 16 bit.
8.20.6
Current status of input 0, 1, 2, 3
This parameter allows you to check the current status of the digital inputs.
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...