Scale parameters and functions
8.3 DR 3 calibration parameters
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
67
Variable
Note
Type
Length
(bytes)
Read/write
protection
Default Min.
Max.
Modbus
registers
(Page 73)
Standstill range (in d)
FLOAT
4
rwP
0.1
0
maximum
number
range+
1048
(Page 73)
Standstill time 1 in ms
TIME
4
rwP
2000
10
10000
1050
(Page 74)
Waiting time until standstill.
0: Any scale commands de-
pendent on standstill are reject-
ed immediately in the absence
of standstill.
>0: Maximum waiting time until
command is executed
TIME
4
rw
2000
0
10000
1052
(Page 74)
Low-pass filter 1 - limit frequen-
cy:
0: Filter disabled
FLOAT
4
rwP
0.5
tbd
tbd
1054
(Page 74)
Ordinal number of low-pass
filter 1:
Filter ordinal number 2*(1 … 5)
USHORT
2
rwP
4
2
10
1056
Reserve 2
Reserve
USHORT
2
rw
0
-
-
1057
(Page 75)
Low-pass filter 2 - limit frequen-
cy:
0: Filter disabled
FLOAT
4
rw
0
tbd
tbd
1058
(Page 75)
Ordinal number of low-pass
filter 2:
Filter ordinal number 2*(1 … 5)
USHORT
2
rw
4
2
10
1060
(Page 75)
Filter for digit values,
permitted filter depth: 0 … 250
USHORT
2
rwP
10
0
250
1061
(Page 75)
Display weighing range data
0: No
1: Yes
USHORT
2
rwP
0
0
1
1062
(Page 75)
Selection of interface for Se-
cureDisplay:
0: HMI control at ETHERNET
1: HMI control via S7 interface
USHORT
2
rw
0
0
3
1063
Firmware
version
SecureDis-
playHeader
Maximum length and actual
length of string for FW version
SecureDisplay
UBYTE[2]
2
rw
12, 12
1064
(Page 75)
FW version of the SecureDis-
play used on the HMI
CHAR[12]
12
rw
1065
Reserve
Reserve
UBYTE[2]
2
rw
0
-
-
1071
Reserve
Reserve
CHAR[20]
20
rw
0
-
-
1072
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...