Scale parameters and functions
8.3 DR 3 calibration parameters
SIWAREX WP231
68
Manual, 07/2014, A5E31238908A-02
Variable
Note
Type
Length
(bytes)
Read/write
protection
Default Min.
Max.
Modbus
registers
Reserve
Reserve
UBYTE[2]
2
rw
0
-
-
1082
Reserve
Reserve
CHAR[20]
20
rw
0
-
-
1083
(Page 76)
Maximum factor for minimizing
the SecureDisplay. Value must
not be smaller than the smallest
value defined in the DisplayCali
file.
USHORT
2
rwP
0
-
-
1093
Reserve 4
Reserve
FLOAT
4
rw
0
-
-
1094
1)
Parameter for calculation of calibration points with theoretical calibration
8.3.2
Scale name
You can select any name, but it may not exceed 12 characters. You can enter any
designation.
Note
The scale name cannot be changed after official verification.
8.3.3
Unit of weight
A string with up to four digits can be specified as the unit of weight, e.g.: t, kg, lbs. The
defined unit of weight applies to all weight specifications. Entries are not be converted if the
unit of weight has changed. Entries must be left-aligned.
8.3.4
Gross identifier
The gross identifier specifies the letter, B (for brutto) or G (for gross), to be used in the
display for gross weights.
8.3.5
Code for regulations
Trade scales requiring official calibration are subject to certain restrictions. The restrictions in
accordance with the OIML directive are activated by entering "1" for OIML R76. Enter "0" to
deactivate the restrictions (function available soon).
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...