Scale parameters and functions
8.5 DR 4 Output of calculated calibration digits
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
81
8.5
DR 4 Output of calculated calibration digits
Data record DR 4 outputs the digits calculated from the automatic scale calibration and the
calibration check. This data record cannot be sent to the scales.
Table 8- 2
Assignment of data record 4
Variable
Note
Type
Length
(bytes)
Rw
Default
Min.
Max.
Modbus
Register
Data record num-
ber
Contains no. of the
data record
USHORT
2
r
4
-
-
1200
Length
Data record length
information
USHORT
2
r
28
-
-
1201
Application
Information on which
application the DR
belongs to
USHORT
2
r
101
-
-
1202
Version identifier Information on
current data record
version
USHORT
2
r
1
1
65635
1203
Calibration digits 0
(calculated):
calibration digits
calculated by 'auto-
matic calibration'
LONG
4
r
200000
0
1600000
1204
Calibration digits 1
(calculated):
calibration digits
calculated by 'auto-
matic calibration'
LONG
4
r
0
0
1600000
1206
Calibration digits 2
(calculated):
calibration digits
calculated by 'auto-
matic calibration'
LONG
4
r
0
0
1600000
1208
Reserve 1
Reserve
SHORT
2
r
0
-
-
1210
Reserve 2
Reserve
USHORT
2
r
0
-
-
1211
Reserve 3
Reserve
FLOAT
4
r
0
-
-
1212
8.5.1
Calibration digits 0, 1, 2 (calculated)
The calculation is based on the parameters from DR 10 and is executed using command no.
82 or 83.
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...