Scale parameters and functions
8.7 DR 6 limit value settings
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
85
Variable
Note
Type
Length
(bytes)
Rw
Default
Min.
Max.
Modbus
Register
(Page 86)
Time for delayed switch-
off of limit value 1 in ms
TIME
4
rw
0
0
maxi-
mum
number
range+
1246
(Page 86)
Switch-on point for limit
value 2 (% of measuring
range)
FLOAT
4
rw
0
maxi-
mum
num-
ber
range
maxi-
mum
number
range
1248
(Page 86)
Time for delayed switch-
on of limit value 2 in ms
TIME
4
rw
0
0
maxi-
mum
number
range+
1250
(Page 86)
Switch-off point for limit
value 2 (% of measuring
range)
FLOAT
4
rw
0
maxi-
mum
num-
ber
range
maxi-
mum
number
range
1252
(Page 86)
Time for delayed switch-
off of limit value 2 in ms
TIME
4
rw
0
0
maxi-
mum
number
range+
1254
(Page 87)
Limit value "empty" ON
(always based on gross
value) (% of measuring
range)
FLOAT
4
rw
0
maxi-
mum
num-
ber
range
maxi-
mum
number
range
1256
(Page 87)
Time for delayed switch-
on of "Empty" in ms
TIME
4
rw
0
0
maxi-
mum
number
range+
1258
Reserve 2
Reserve
USHORT
2
rw
0
-
-
1260
Reserve 3
Reserve
USHORT
2
rw
0
-
-
1261
Reserve 4
Reserve
FLOAT
4
rw
0
-
-
1262
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...