Scale parameters and functions
8.8 DR 7 interface parameters
SIWAREX WP231
88
Manual, 07/2014, A5E31238908A-02
8.8
DR 7 interface parameters
Data record DR 7 contains the parameters for defining the properties of the available I/O
modules (digital inputs, digital outputs, analog output, serial ports).
If a port is not used, the default values can be retained.
Procedure
●
Change the parameters if necessary
●
Transfer the data record to the scales
Table 8- 5
Assignment of data record 7
Variable
Note
Type
Length
(bytes)
RW
Default
Min.
Max.
Modbus
Register
Data record
number
Contains no. of data record
USHORT 2
r
7
-
-
1300
Length
Data record length infor-
mation
USHORT 2
r
60
-
-
1301
Application
Information about which
application the DR belongs
to
USHORT 2
r
101
-
-
1302
Version identifier Information about the current
data record version
USHORT 2
r
1
1
65635
1303
Assignment for input 0:
Code 0: No command as-
signed
1 … 32767: Command is
triggered at a rising edge (0-
>1 transition)
USHORT 2
rw
0
0
1999
1304
Assignment for input 1:
Code 0: No command as-
signed
1 … 32767: Command is
triggered at a rising edge (0-
>1 transition)
USHORT 2
rw
0
0
1999
1305
Assignment for input 2:
Code 0: No command as-
signed
1 … 32767: Command is
triggered at a rising edge (0-
>1 transition)
USHORT 2
rw
0
0
1999
1306
Assignment for input 3:
Code 0: No command as-
signed
1 … 32767: Command is
triggered at a rising edge (0-
>1 transition)
USHORT 2
rw
0
0
1999
1307
0: 0.2 ms
1: 0.2 ms
2: 0.4 ms
3: 0.8 ms
4: 1.6 ms
5: 3.2 ms
6: 6.4 ms
7: 12.8 ms
USHORT 2
rw
5
0
7
1308
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...