Scale parameters and functions
8.8 DR 7 interface parameters
SIWAREX WP231
92
Manual, 07/2014, A5E31238908A-02
8.8.4
Response of digital outputs to faults or SIMATIC STOP
This parameter allows you to define the response of the digital outputs following a fault of the
SIWAREX module or SIMATIC STOP.
Value
Response
0
Outputs are switched off
1
Outputs are not switched off (continue)
2
The relevant substitute value is activated
3
Outputs are switched on
8.8.5
Substitute value for DQ 0, 1, 2, 3 following fault or SIMATIC STOP
The outputs are usually reset following a module fault (operating error) or SIMATIC CPU
STOP. This response is the default setting.
If an output is to be set following a fault, this response is defined using this parameter. The
"Response of digital outputs to fault or SIMATIC STOP" parameter must also be set to
"Output substitute value".
The substitute value definition is then valid.
Examples
Table 8- 6
Bit 0 defines digital output 1 (DQ 1)
Value of bit 0
Value of DQ 1 following fault
0
0
1
1
Table 8- 7
Bit 1 defines digital output 2 (DQ 2)
Value of bit 2
Value of DQ 2 following fault
0
0
1
1
NOTICE
Risk to the plant
If an output is set following a fault (operating error), this can pose a risk for the plant.
Ensure that the parameters are correctly set.
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...