Scale parameters and functions
8.14 DR 14 SIMATIC interface parameters
SIWAREX WP231
106
Manual, 07/2014, A5E31238908A-02
8.14.2
Selection of process value 1, 2
The weighing module can communicate with an S7-1200 CPU in two ways: Just via the I/O
or by reading out complete data records. The I/O is faster and exhibits a higher performance.
Two free-definable channels are available in the S7 I/O (process value 1 and process value
2). Users can decide which scale values (see table) are to be made available cyclically at
these two parameters of the PLC.
Table 8- 14 Selection table for process value 1,2
Process value
Decimal code
From DR
Format
No process selected
0
-
-
Gross process
1
30
FLOAT
Net process
2
30
FLOAT
Tare process
3
30
FLOAT
Legal trade G/N weight
4
30
FLOAT
G/N weight_x10
5
30
FLOAT
Legal trade tare weight
6
30
FLOAT
Gross-2-process-value
7
30
FLOAT
Net-2-process-value
8
30
FLOAT
Unfiltered digit value
9
31
LONG
Filtered digit value
10
31
LONG
Filtered digit value 2
11
31
LONG
Refresh counter
12
30
USHORT
Status of analog output, digital outputs,
and digital inputs
13
31
WORD, BYTE
Table 8- 15 Structure of status of analog output, digital outputs, and digital inputs
Byte 0 of
dw_ProcessValue1/2
Byte 1 of
dw_ProcessValue1/2
Byte 2 of
dw_ProcessValue1/2
Byte 3 of
dw_ProcessValue1/2
Analog output digits
HIGH
Analog output digits LOW
Status of digital outputs
Status of digital inputs
WORD
Bit 0 = status DQ 0
Bit 0 = status DI 0
Bit 1 = status DQ 1
Bit 1 = status DI 1
Bit 2 = status DQ 2
Bit 2 = status DI 2
Bit 3 = status DQ 3
Bit 3 = status DI 3
See also
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...