Scale parameters and functions
8.22 DR 34 ASCII main display value
SIWAREX WP231
124
Manual, 07/2014, A5E31238908A-02
8.22.2
Content of main display as ASCII string
The following values can be displayed in non-automatic weighing instruments (NAWI)
applications:
Gross process value
From DR 30
Net process value
From DR 30
G/N weight
From DR 0
G/N weight x10
From DR 30
Tare
From DR 30
Gross_2 process value
From DR 30
Firmware version
From DR 9
Current calibration regulation
From DR 9
Serial number of module
From DR 9
Below are some display examples. Commands are used to toggle display values.
The values to be displayed are hidden if, for example, a fault is pending or a value is outside
the valid display range.
Value designation
Blank
Display value
Unit of weight
(from DR 3)
Weight
(Tare
≠ 0)
NET
•
•
•
•
•
2 2 0 . 5 0
•kg•
Weight
(Tare = 0)
B
•
•
•
•
•
•
- 0 . 0 3
•t••
Operator error
•
•
•
•
•
•
1 0 . 0 0 3 HIGH
Weight simulation activated
B
•
•
•
•
•
•
E r r o r
TEST
Max+9e exceeded
B
•
•
•
•
•
•
- 0 . 0 3 ****
Tare display activated (pt)
p
T
•
1 2 5 6 7 8 . 9 0
•kg•
Tare display activated
T
•
•
•
•
•
•
5 0 . 5 0
•kg•
NET = net
B = gross
T = tare
pT = preset tare (tare setting active)
S = sum
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...