Scale parameters and functions
8.23 DR 45 protocol request
SIWAREX WP231
Manual, 07/2014, A5E31238908A-02
125
8.23
DR 45 protocol request
8.23.1
Overview
Scale logs can be saved in the internal memory of the SIWAREX. If necessary, a log can be
read out calibration-proofed using the SIWATOOL V7 program or the SecureDisplay and its
contents checked.
Using data records DR 45/DR 46, you can read all logs into the SIMATIC S7 (not calibration-
proofed, only as operating information). The users enters the desired protocol ID in DR 45
and subsequently sends DR 45 to the SIWAREX. The protocol is then made available in DR
46 for reading out.
Table 8- 24 Assignment of data record 45
Variable
Note
Type
Len
gth
(byt
es)
Rw Default
Min.
Max.
Modbus regis-
ters
Data record number
Contains no. of data record
USHORT
2
r
45
6000
Length
Data record length information
USHORT
2
r
28
6001
Application
Information about which applica-
tion the DR belongs to
USHORT
2
r
101
6002
Version identifier
Information about current data
record version
USHORT
2
r
1
1
65635
6003
Reserve
Reserve
UBYTE[2]
2
rw
12,12
6004
Reserve
Reserve
CHAR[12]
12
rw
" "
-
-
6005
Reserve
Reserve
USHORT
2
rw
0
6011
Protocol ID to be
read, decimal
ID of requested protocol entry as
decimal value
LONG
4
rw
0
1
6012
8.23.2
Protocol ID to be read
The protocol ID of the protocol to be displayed in data record 46 is entered at this point.
The report ID to be read is also used for reading of the report for legal trade use by means of
the SecureDisplay.
Summary of Contents for SIWAREX WP231
Page 16: ...Safety notes 2 1 General safety instructions SIWAREX WP231 16 Manual 07 2014 A5E31238908A 02 ...
Page 132: ......
Page 174: ...Technical data 13 3 Approvals SIWAREX WP231 174 Manual 07 2014 A5E31238908A 02 ...
Page 180: ...List of abbreviations SIWAREX WP231 180 Manual 07 2014 A5E31238908A 02 ...
Page 182: ...Index SIWAREX WP231 182 Manual 07 2014 A5E31238908A 02 ...