User programming via the keypad
7
User Menus
33
Siemens AB
A6V10271018
Security Products
26.09.2011
7.1.10
SMS
The SPC system support SMS communication from the panel to selected users’
mobile phones as well as users being able to control the SPC system remotely via
SMS. These two features work hand in hand as it allows the user to take action
using the SMS control after a SMS notification without the need to be physically at
the premises.
SMS control
The SMS control can be set up so that a remote user can send a SMS message to
perform the following actions at the panel:
Setting / unsetting
Enable / disable engineer
Enable / disable manufacturer access.
Mapping gate on/off.
SMS events
The SMS notification can be set up to send a range of events that occur on the
system such as:
Alarm activation
Confirmed alarms
Fault & tamper
Setting & unsetting
Inhibit & isolate
All other types of events
The SMS notification can operate with a PSTN modem if the PSTN operator
supports SMS over PSTN where as SMS control will need a GSM modem at the
panel. A GSM modem will support both SMS notification and control.
7.1.10.1
SMS CONTROL
There is a maximum of four users for SMS configuration on 1 panel and only 1
phone number for each user for use with SMS control functionality.
It is important prerequisites such as an SMS-enabled modem and correct user
profile are met for SMS control.
Depending on the SMS AUTHENTICATION MODE (OPTIONS menu) chosen by
the installation engineer, the user’s mode of SMS may vary.
If the system SMS authentication is set to the SMS PIN Code, Caller ID or PIN &
Caller ID, it is necessary to set up SMS control:
1. Scroll to SMS CONTROL and press SELECT.
2. Select the desired configuration option shown in the table below.
3. Press BACK to exit.