API or SPO Penetrators
Figure 5 - Recommended lift positions - Penetrators
Dummy, or parking connectors weigh less than 15 kg and can be lifted by hand, however correct
lifting practice should be observed at all times.
CONNECTORS/PENETRATORS SHOULD NEVER BE LIFTED BY THE HOSE OR CABLE,
AS THIS PLACES UNNECESSARY STRAIN ON THE CONNECTOR INTERNALS AND
MAY RESULT IN LOSS OF CONTINUITY.
On harnesses, the cable or hose should be supported during lifts to minimise strain on the
Connector/Penetrator. The maximum recommended length of hose which can be unsupported
during a lifting operation is
5 meters
.
Protective caps should remain on wherever possible during lifting operations to minimise the risk of
damage to connector sealing or electrical components. This particularly applies to penetrators.
Affix suitable lifting eye
SPO = M12 x 20mm max
API = M16 x 25mm max