Page
22
Document Number: 0072
Rev. 09
CONTROLLED COPY
Figure 16 - Connectors fully mated.
Note small gap between flanges when fully mated.
9.2 DE-MATING PROCEDURE
Prior to commencing the de-mating of the connector pair it is assumed that the Receptacle connector
is mounted in its associated structure, and a Plug connector is mated to it.
1.
The operator should brace himself using the grab bars or other provided interfaces, and ensure
the connector is at chest height.
2.
By gripping the ROV handle
(as shown in Figure 14), the connector should be de-mated from
the Receptacle using one smooth pulling movement along the axes of the connectors. A force
of 40kgf (392N) will be required to de-mate the connectors.
Note; the connector latch is automatically depressed by pulling the ROV handle.
3.
When the Plug connector is fully separated from the receptacle connector, if appropriate it can
then be mated to the parking Receptacle, using the steps mentioned in the mating procedure
above.
A dummy plug should also be mated to the remaining receptacle, again using the
procedure above.
Summary of Contents for SpecTRON 5