Copyright © Siemens plc 2014. All Rights Reserved. Mobility and Logistics is a division of Siemens Plc
•
HTTPS (TCP 443)
o
(TLS trusted time)
o
o
(OpenVPN)
•
HTTP or HTTPS (TCP 80 or 443)
o
OCSP authenticator for stratosemerge HTTPS certificate (OCSP)
Other applications and features of the equipment may require access to additional
services either on the internet or on a local network. The documentation for these
applications and features record these requirements.
Licence Card
A Licence Smartcard version 2 is required to support connections to Stratos. The version
of the Licence Smartcard fitted can be checked on the System – Settings – Comms –
Stratos configuration web page.
The UTMC OTU licence controls whether or not connection to Stratos is supported – see
section 3.17.
Ethernet Configuration
Ethernet can be fully configured manually if required but configuration can be minimised
by using DHCP.
To connect the equipment to Stratos perform the following:
1. Set the date and time (
System - Settings - System Date & Time - Set System Date
& Time
web page).
2. On the
System - Settings - Comms – Stratos
web page:
•
Set the Tenant Pass Phrase.
•
Set the Site Location.
•
Set the Site Name.
3. Set the profile to Stratos (
System – Settings
web page).
4. Check that Ethernet is suitably configured (
System - Settings - Comms - DSL/Fibre
web page). Using the Stratos profile sets this to DHCP. If this not suitable then
configure as required.