Mobility, Intelligent Traffic Systems
Sopers Lane, Poole, Dorset, BH17 7ER
Security
classification Unrestricted
Page
51 of 92
Version
3
Status
Issued
Last Editor
Alan Doyle
Date
05-Oct-2017
Document Name
Stratos Outstation General and ICM Handbook Document No. 667/HB/52250/000
Copyright © Siemens plc 2014. All Rights Reserved. Mobility and Logistics is a division of Siemens Plc
4.9
The Intelligent Detector Backplane
The Stratos Outstation can be connected to intelligent detector backplane(s) for better
integration with detectors. Each IDB can be used with up to four loop detectors and
provides a GSPI interface which removes the need to wire discrete detector outputs into
I/O board inputs and provides a mechanism for terminating the street loop wiring for 16
loops for each backplane fitted. Each IDB must be addressed in the same manner as any
GSPI I/O board as described in Section 4.8.5.
The Intelligent Detector Backplane Kit part number is 667/1/32910/950.
Whenever detectors are used a separate detector supply kit will be required unless there
is spare capacity on a detector supply that is already available within the cabinet. Four
detector supply kits are available as shown below:
Description
Part Number
ST900ELV Detector Supply Kit – 2A
(-24V Rectified AC, ELV Compliant)
667/1/33075/000
ST900ELV Detector Supply Kit – 6A
(-24V Rectified AC, ELV Compliant)
667/1/33074/000
ST800/ST900 Detector Supply Transformer – 2A (24V AC)
667/1/27853/000
ST800/ST900 Detector Supply Transformer – 6A (24V AC)
667/1/20292/008