I/O & PSU Card
LED
State
Description
SYS / RUN
System / Run
(Green)
Slow Flash
Normal Operation.
Medium Flash
Configuration or Firmware Download in progress.
Double Pulse
Low power mode.
COMMS
Communications
(Green)
On
Normal operation, GSPI messages being received
regularly.
Off
No relevant GSPI messages received in the last
second (implies loss of communications), or low
power mode.
FLT – Fault
(Red)
Off
Normal operation.
On
Fault detected. Refer to Table 10 and Table 19 for
details of possible faults.
Double Pulse
Firmware is in Error and low power mode.
Table 28 – PSU & I/O Board LED States
5.14 Testing, Validation and Site Acceptance
The installation should be tested in accordance to the relevant section for the feature(s)
used.
Run the system test scenario.
Site Acceptance Test (SAT) sheet (667/CI/31601/002) should be followed and completed
to ensure that the installation has been completed to a good standard, and that the
outstation is running properly.
The Relevant Setup Form (dependant on feature(s) used) should be completed and left in
the controller cabinet.
Eg. Stratos Outstation UTMC Commissioning Data 667/CI/52250/000