IOM-007
Installation Operation Manual for TC3A-107 and Similar EDUs
Page 18 of 19
14.
AQUATRON HOSE SPECIFICATION
Figure 14 – AquaTRON hose size 50 & 75
Design life: 30 years
External pressure: 0 to 400 bar (depth pressure)
Recommended fill pressure: 15 bar
Deployment rate: 10 metres / minute
Operational temperature range: -5°C to +55°C
Hose Burst Strength: 90 Bar
Max twisting of AquaTRON Hose: 180° per 5m length
Recommend hose be protected with tarpaulin sheet or equivalent if in direct sunlight.
Axial loads for AquaTRON oil tube
AquaTRON hose can withstand an axial load of 5000N. It has been tested to failure at 11000N.
If cable ties are used leave loose on the hose. Do not compress.
Chemical Compatibility for AquaTRON oil tube
For chemical compatibility use with AquaTRON oil tube see qualification report TR-422 section
3.11 and ERP-001-06.
15. MAINTENANCE
All EFL’S are designed for Subsea immersion and require no maintenance while installed.
15.1 Protection of Receptacle Contact Pins
Under no circumstances must the contact pins in the receptacle connector be exposed to
seawater with power on. If this situation does occur the contact surfaces of the pins will very
rapidly degrade by electrolytic action. If these damaged pins are subsequently mated into a
socket insert there is a
very high risk
of damage to the insulation and seals within the plug
connector.
15.2 Over Current Capacity
Over current capacity for all DigiTRON connectors is 100A for 5 seconds at no more than 2 per
hour.