TC65 Terminal Hardware Interface Description
Confidential / Released
s
TC65 Terminal_HD_V02.000b
Page 50 of 65
19.02.2007
The following table shows the longest possible duration of a connection until 81°C
(Temperature of GPRS Class Change) are reached at the NTC when the ambient
temperature is 65°C.
Table 24: Longest duration until 81°C are reached
Terminal horizontal, normal position
Longest possible duration of connection
GPRS Class 10 PCL5/Gamma3
11 minutes
GPRS Class 12 PCL5/Gamma3 with Power Reduction
7 minutes
GPRS Class 12 PCL5/Gamma3 without Power Reduction
---
The following table shows the longest possible duration of connection when the GPRS
Class Change from GPRS Class 12 or 10 to GPRS Class 8 did not work properly and 90°C
(Temperature of Hardware shut off) will be reached at the NTC (ambient temperature is
65°C).
Table 25: Longest duration when GPRS Class Change does not work properly
Terminal horizontal, normal position
Longest possible duration of connection
GPRS Class 8 PCL5/Gamma3
Continuous operation
GPRS Class 10 PCL5/Gamma3
22 minutes
GPRS Class 12 PCL5/Gamma3 with Power Reduction
14 minutes
GPRS Class 12 PCL5/Gamma3 without Power Reduction
---