TC65 Terminal Hardware Interface Description
Confidential / Released
s
TC65 Terminal_HD_V02.000b
Page 52 of 65
19.02.2007
5.2
Characteristics of On/Off control
Table 27: Characteristics On/Off control
Function
Signal name
IO Signal form and level
Comment
Emergency
OFF
EMERGOFF
I
R
I
≈
100kOhm
V
L
max = 0.8V
V
L
min = -0.3V
V
H
min = 4.5V
V
H
max = 30V
signal
___________|
~~~~~~~~~~~~
|__
|
≥
1s |
≥
1s |
Rise time
≤
100ms
Emergency-off switches
the power supply of the
Terminal off.
Data stored in the volatile
memory will be lost, if used
the emergency off.
If unused keep pin open.
IGT_IN
I
R
I
≈
100kOhm, C
I
≈
100nF
V
L
max = 0.8V
V
L
min = -0.3V
V
H
min = 8V
V
H
max = 30V
signa
l ___________|
~~~~~~~~~~~~
|__
|
≥
0.5s |
≥
0.5s |
Rise time
≤
100ms
This signal switches the
mobile ON.
It´s possible to connect
IGT_IN directly with
POWER.
If unused keep pin open.
Ignition
ONOFF
I
R
I
≈
30k
Ω
, C
I
≈
10nF
V
IL
max = 0.5V at Imax = -150µA
V
OH
max = 4.2V
ON OFF
~~~~
|________|
~~~~~~~~~~~~~
|________|
~~~
|
≥
0.4s |
≥
2s |
≥
1s |
Rise time
≤
1ms
This signal switches the
mobile ON and OFF.
This line must be driven
low by an open drain or
open collector driver.
If unused keep pin open.
RS232 DTR
I
V
I
min = ±3V
signal
~~~
|________|
~~~~~~~~~~~~~~~
|
≥
0.5s |
≥
0.5s |
Rise time
≤
1ms
This signal switches the
module ON with the low