Appendix F – Example CSV File
The CSV file contains the allocation of control and reply bit functions for the outstation.
The file is generated automatically at the UTC instation by using the “Download OTU
Mapping CSV file” link from the outstation data preparation screen. The file can be
imported as described in section 6.2.3.
# UTMC OTU equipment function mapping table for X11990 generated on Mon Dec 7
10:42:56 2009
#SiteID, Function, Instance, Direction, Description, Offset, Param 1, Param 2,
Card/Port, Bit
J11991, Gn, 1, In, "GA: Green confirm for stage", 1, 0, 0
J11991, Gn, 2, In, "GB: Green confirm for stage", 2, 0, 0
J11991, Gn, 3, In, "GC: Green confirm for stage", 3, 0, 0
J11991, Gn, 4, In, "GD: Green confirm for stage", 4, 0, 0
J11991, Gn, 5, In, "GE: Green confirm for stage", 5, 0, 0
Z11991, GPn, 1, In, "RQ: Unspecified remote request or notification", 6, 0, 0
Z11992, GPn, 1, In, "RQ: Unspecified remote request or notification", 7, 0, 0
Z11993, GPn, 1, In, "RQ: Unspecified remote request or notification", 8, 0, 0
J11991, MR, 1, In, "MR: reply to confirm that MO control bit seen", 9, 0, 0
J11991, ML, 1, In, "ML: reply to confirm MOVA operating normally - up to 4 mins after
MR", 10, 0, 0
J11991, MF, 1, In, "MF: MOVA detected a fault", 11, 0, 0
D11991, VC, 1, In, "VC1: Vehicle count bit", 12, 2, 0
D11991, VO, 1, In, "VO: Vehicle occupancy bit", 13, 0, 0
Q11991, VQ, 1, In, "VQ: Queue detected bit", 14, 0, 0
Q11991, DF, 1, In, "DF: Detector fault", 15, 0, 0
X11990, VSn, 1, In, "VS1: N01111A3: SCOOT detector occupancy", 17, 0, 0
X11990, VSn, 2, In, "VS2: N01111A4: SCOOT detector occupancy", 21, 0, 0
X11990, VSn, 3, In, "VS3: N03151R1: SCOOT detector occupancy", 25, 0, 0
X11990, VSn, 4, In, "VS4: N01111A5: SCOOT detector occupancy", 29, 0, 0
J11991, Fn, 1, Out, "FA: Controller force bits for stage", 1, 0, 0
J11991, Fn, 2, Out, "FB: Controller force bits for stage", 2, 0, 0
J11991, Fn, 3, Out, "FC: Controller force bits for stage", 3, 0, 0
J11991, Fn, 4, Out, "FD: Controller force bits for stage", 4, 0, 0
J11991, Fn, 5, Out, "FE: Controller force bits for stage", 5, 0, 0
J11991, MO, 1, Out, "MO: set to change junction to MOVA control", 9, 0, 0
F11991, SFn, 1, Out, "SF: Special facility output", 49, 0, 0
J11991, TC, 1, Out, "TC: Transmission Confirm", 0, 0, 0, csi.utc.to.out.1, 1
J11991, MOVACRB, 1, In, "MOVACRB: MOVA Controller Ready Bit", 0, 0, 0,
csi.crb.in.1, 1