This field can only be changed when the bit is being added using the 'Add Bit
Table'
The available UTC control functions are:-
Item
Use
CP
Close Car Park
Dn
Stage Demand
DX
Common demand
EP
Bus Extension Permit
FF
Signals Flashing
FM
Fallback Mode (inhibit CLF)
Fn
Stage Force
GO
Gap Out
HI
Hurry Call Inhibit
LL
Local Link Inhibit
LO
Signals On
MO
MOVA Override
PV
Hold Vehicle
PX
Pedestrian Demand
SFn
Switch Facility
SG
CLF Group Sync
SO
Solar Override (to bright)
TC
Transmit Confirm – This bit is set to ‘1’ by the OTU while UTC
messages are being received from the instation.
TO
Take Over
TS
Time Sync
The following output functions are generated locally, for use with MOVA:-
MOVATO
MOVA Take Over
MOVAES1LIn MOVA end of saturation flow type 1 on link
MOVAES2LIn MOVA end of saturation flow type 2 on link
MOVAES3LIn MOVA end of saturation flow type 3 on link
MOVAES4LIn MOVA end of saturation flow type 4 on link
MOVAES5LIn MOVA end of saturation flow type 5 on link
MOVAES6LIn MOVA end of saturation flow type 6 on link
MOVAES7LIn MOVA end of saturation flow type 7 on link
MOVAES8LIn MOVA end of saturation flow type 8 on link
MOVAES9LIn MOVA end of saturation flow type 9 on link
MOVAESLIn
MOVA end of saturation flow (any type) on link
MOVAOSATn MOVA oversaturation on lane