UTMC OTU/MOVA Handbook
667/HB/31601/000
Page 56
Issue 5
every day. If a new logging period is required to start immediately then the export
start date-time should be changed to the current time.
6.6.5 Controller Serial Link Screen
Enable Semi-Integral Link to Siemens Controller
Select to Enable the Semi-Integral Link to Siemens Controller. The semi-integral
link carries data for UTC, MOVA, detectors, faults and controller handset.
Disable for freestanding OTU. Default Enabled.
Freestanding Controller Serial Port Baud Rate
Select the baud rate for the serial handset interface to a freestanding controller.
For Semi-Integral Link to Siemens ST700/750/800/900 family controllers, the
value is not used.
Controller Diagnostics Upload Interval
Defines the time interval between each retrieval of the controllers Current Fault
Flags, and Historic Fault Log. Range 5 to 1440 minutes. Current fault flags are
asserted in the main Gemini Fault Table. The Historic Fault Log may be found in
the Controller Log tab. Default 10 minutes.
Controller Settings Files Upload Interval
Defines the time interval between each automatic retrieval of the controllers 8UL
file and UDD file. Range 10 to 10080 minutes. The 8UL file is an IC4 compatible
compressed version of the original controller configuration file, for back up
purposes. The UDD file contains a subset of controller settings, and may be
viewed and edited in Convert. It may then be sent back to the controller to effect
settings changes. Default 1440 minutes (24 hours).