UTMC OTU/MOVA Handbook
667/HB/31601/000
Page 79
Issue 5
Siemens MOVA Commissioning Complete
7.2.1 Re-initialising MOVA
If it is required to clear the MOVA data sets and working data, then the
movaini
command can be used:
movaini1
- this will initialise MOVA stream 1
movaini2
- “ “ “ stream 2
movaini3
- “ “ “ stream 3
movaini4
- “ “ “ stream 4
If the command is not recognised, the MOVA application for that stream must be started
running (to view running applications, use the web interface and display the “System”
web screen).
When the command is executed, the MOVA data sets, MOVA working data, MOVA
error logs, flow logs and assessment logs for that MOVA stream are restored to the first
time start-up state. Other MOVA streams will be unaffected.
In the case of MOVA 7 the OTU should then be rebooted to ensure clean erasure of
TMA log data from the file system and working memory.