Closing checklist
7. Re-attach front panel wiring
If required, there are three points to re-connect:
1. Wiring to the top, rear panel.
Plug in connector.
2.
Earthing
strap.
Replace the earthing strap lug on the stud and secure with
the nut using a 10mm socket.
3. Connector ‘B’ on the HMI panel.
Plug in Connector ‘B’.
8. Attach front panel
Gently place the front panel on the top hook ensuring the
panel sits outside the fastening brackets. Check that the top
hook is engaged. It will hold in position. Secure with the nylon
washers and security screws with the 5mm Pin Hex tool
ensuring the plastic holes line up with the bracket nutserts. Do
not over tighten.
The Ultra 50 fast charger is now ready for operation.
1
2
3
Published by Siemens Industry, Inc. 2020
Siemens Industry, Inc.
3617
Parkway
Ln.
Peachtree Corners, GA 30092
Phone: +1 (800) 333-7421
info.us@siemens.com
usa.siemens.com/versicharge
Article
No.
SIDS-T40045-00-4AUS
Printed in USA
All Rights Reserved
© 2020, Siemens Industry, Inc.
The technical data presented in this document is based on an actual case or on
as-designed parameters and, therefore, should not be relied upon for any
specific application and does not constitute a performance guarantee for any
projects. Actual results are dependent on variable conditions. Accordingly,
Siemens does not make representations, warranties, or assurances as to the
accuracy, currency or completeness of the content contained herein. If
requested, we will provide specific technical data or specifications with respect
to any customer’s particular applications. Our company is constantly involved
in engineering and development. For that reason, we reserve the right to
modify, at any time, the technology and product specifications contained
herein.
VersiCharge Ultra 50™ |
Installation Manual
Summary of Contents for VersiCharge Ultra 50
Page 2: ...2 ...