54
Siemens Building Technologies
Fire Safety & Security Products
10.2008
Test Description
Result Type
Result Data
Cards Test Exceptions
Card tests passed
Total cards tested
Total cards
Card firmware version is incompatible
Card with wrong
version
Rack number (always 1),
Slot,
Version found
Card PCB version is incompatible
Card with wrong
version
Rack number (always 1),
Slot,
Version found
Card LED register not responding
Card with bad
register
Rack number (always 1),
Slot,
Type
Comms card loopback failure
Card that failed
Rack number (always 1),
Slot,
Channel
Telemetry card loopback failure
Card that failed
Rack number (always 1),
Slot,
Channel
Card test exception buffer full
None
None
Auto-Detection Test Exceptions
Auto-detection tests passed
Total rack frames
and cards detected
Rack frames (always 1),
Total cards
Card type is unknown
Card with wrong
type
Rack number (always 1),
Slot,
Type
Too many cards of one type
Card type details
Type,
Number allowed,
Number detected
Valid Flash hardware configuration is different
from auto-detected one. Flash configuration
used.
None
None
Auto-detection test exception buffer full
None
None
Video Routing Test Exceptions
Video routing tests passed
Total routes tested
Total routes tested
No input video source detected
None
None
Sync not detected at correct output channel
Camera and correct
monitor
Camera,
Monitor
Sync detected at wrong output channel
Camera and wrong
monitor
Camera,
Monitor
No sync detected at any output channel
Camera
Camera
Video routing test exception buffer full
None
None
SRB Error Exceptions
SRB slot status register
Register contents
Rack number (always 1),
Slot,
Register value
SRB error exception buffer full
None
None
Self-test Results Summary
Summary: total passes, warnings, failures
Summary of all test
results
Passes,
Warnings,
Failures
Tab. 41
VisiPC self-test results
NOTE