Siemens Industry, Inc.
Building Technologies  Division
Florham Park, NJ

Siemens Canada, Ltd.
1577 North Service Road East
Oakville, Ontario
L6H 0H6 Canada

P/N 315-050490-3

Document ID A6V10316286

Summary of Contents for VNT

Page 1: ...system 100BaseTTCP IP connection to a local Fiber Ring Switch This connection transports the network signals HNET and XNET audio supervision and monitoring data streams One or more independent HNET RS485 interfaces to the module network of an XLS Desigo Fire Safety Modular Cerberus PRO Modular or its components An XNET RS485 interface to the XLS Desigo Fire Safety Modular Cerberus PRO Modular node...

Page 2: ...hem to secure the VNT to the VNT MP VNT STUDS 4 FOR MOUNTING VNT VNT MP FIBER SWITCH MOUNTING RAIL XND BRACKET Figure 2 Mounting the VNT to the VNT MP WIRING Wiring for the VNT Building Configuration is shown in Figure 3 Wiring for the VNT Fire Command Center is shown in Figure 4 All connections are supervised and power limited unless otherwise stated ELECTRICAL RATINGS For power the VNT may only ...

Page 3: ...ologies Division P N 315 050490 3 3 FIRE SYSTEM TO P5 1 1 19 1 1 _ _ _ 2 2 H N GND 6 24 12 18 7 13 1 2 3 4 TB1 TB2 BATTERY P9 P12 TB3 TB4 P4 OFF O ON P10 HNET CAN 1 2 3 4 5 1 2 3 4 5 P3 1 2 E5 Figure 3 Connection Diagram for VNT Building ...

Page 4: ... 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 LCM 8 OR SCM 8 LCM 8 OR SCM 8 LCM 8 OR SCM 8 LCM 8 OR SCM 8 LCM 8 OR SCM 8 LCM 8 OR SCM 8 LCM 8 OR SCM 8 LCM 8 OR SCM 8 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 P1 P2 Buzzer 12345678 12345678 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 ...

Page 5: ...eeds Such a security concept may result in additional site specific preventive action to ensure that the building comfort fire safety security management or physical security system for your site are operated in a secure manner These measures may include but are not limited to separating networks physically protecting system components user awareness programs defense in depth etc For additional in...

Page 6: ...Siemens Industry Inc Building Technologies Division P N 315 050490 3 6 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ...

Page 7: ...Siemens Industry Inc Building Technologies Division P N 315 050490 3 7 THIS PAGE HAS BEEN LEFT INTENTIONALLY BLANK ...

Page 8: ...Siemens Industry Inc Building Technologies Division Florham Park NJ Siemens Canada Ltd 1577 North Service Road East Oakville Ontario L6H 0H6 Canada P N 315 050490 3 Document ID A6V10316286 ...