Installation
4.7 Mounting the input or output element on the gearbox
BA 2012
22
Operating Instructions, 03/2013, 70000004024300
4.7
Mounting the input or output element on the gearbox
WARNING
Danger of burns due to hot parts
Do not touch the gearbox without protection
NOTICE
Damage to shaft sealing rings caused by solvent or benzine
Avoid contact at all times.
NOTICE
Damage to shaft sealing rings caused by heating over 100 °C
Protect shaft sealing rings from heating up due to radiant heat using thermal shields.
NOTICE
Alignment errors caused by excessive angle or axial displacement of the shaft ends to be
joined lead to premature wear or material damage
Ensure precise alignment of the individual components.
NOTICE
Damage to bearings, housing, shaft, and locking rings due to improper handling
Do not use impacts or knocks to force the input and output elements to be mounted onto
the shaft.
Note
Deburr the parts of elements to be fitted in the area of the hole or keyways.
Recommendation: 0.2 x 45°
Where couplings are to be fitted in a heated condition, observe the specific operating
instructions for the coupling. Unless otherwise specified, the heat can be applied inductively,
using a torch or in a furnace.
Use the centering holes in the shaft end faces.
Summary of Contents for Worm Gearbox S 5 BA 2012
Page 1: ...Answers for industry MOTOX MOTOX Worm Gearbox S BA 2012 Operating Instructions 03 2013 ...
Page 2: ......
Page 34: ...Commissioning BA 2012 32 Operating Instructions 03 2013 70000004024300 ...
Page 36: ...Operation BA 2012 34 Operating Instructions 03 2013 70000004024300 ...
Page 44: ...Disposal BA 2012 42 Operating Instructions 03 2013 70000004024300 ...
Page 53: ......