Installation
4.11 Mounting the motor
BA 2012
30
Operating Instructions, 03/2013, 70000004024300
The torque arm can be fitted in various positions, depending on the hole circle pitch.
Procedure
1.
Clean the contact surfaces between the housing and the torque arm.
2.
Tighten the bolts M6 to 10 Nm torque.
You have now mounted the torque arm.
4.11
Mounting the motor
NOTICE
If geared motors are inadequately sealed, moisture can enter the motor
If installing the geared motor outdoors or if a higher degree of protection applies (≥ IP55),
the flange, screws, and installed elements must be sealed with an appropriate sealing
compound.
The flange-mounted motor must be sealed across the entire contact surface.
Figure 4-8
Mounting the motor