Operation
ATEX version gearboxes
The difference between the temperature of the housing and the ambient
temperature of max. +40 °C must not exceed 70 K.
Using a suitable temperature sensor, measure the temperature at the lowest point
of the housing (oil sump) or at the mounting surface in the case of output units.
Changes are an indication of possible incipient damage.
CAUTION
Faults can cause damage to the gearbox or personal injuries
In the event of changes during operation, the drive unit must be switched off immediately.
Use the fault table in the section titled "Faults, causes, and remedies" to determine the
cause of the fault.
Remedy faults or have faults remedied.
Check the gearbox during operation for:
● Excessive operating temperature
● Changes in gear noise
● Possible oil leakage at the housing and shaft seals.