Building Technologies 

Network Node WTT16…, WTX16… 

CE1N2874en 

HVAC Products 

 

14.07.2005 

Functions 

  Reception and storage of the data transmitted by the Siemeca™ AMR consumption 

meters 

  Automatic creation of a network with up to 12 WT…16 (with a maximum of 500 con-

sumption meters) 

  Passing on all relevant consumption values to all WT…16 on the network 

  Communication via the Siemeca™ gateway 

  Communication with the OZW10 M-bus central unit  

Network node versions 

The WT…16… network node is a component of the Siemeca™ system and has been 
designed for exclusive use with that system.  
It is available in a number of versions for different applications: 
 

Application Battery-powered 

Mains-powered 

Standard 

WTT16 WTX16 

With RS-232 interface for local data readout 

WTT16.232 WTX16.232 

 
Network nodes with integrated gateway are used for the remote readout of Siemeca™ 
AMR networks. They are described in data sheet N2878. 

Combinations 

All network nodes with integrated gateway can be used along with any other network 
node. The maximum number of 12 network nodes in one system must not be ex-
ceeded. 
The network nodes with gateway and integrated M-Bus master (WTX16.GSM and 
WTX16.IP) are able to read M-Bus meters according to EN1434/3. 

Technical design 

The network node consists of the following subassemblies: 

tr

ans

ceiv

er for

 Siem

ec

a™

 network

memory for
500 meters

M-Bus

(Slave)

RS232

(optional)

backup battery

power supply:

mains supply WTX16..

battery WTT16...

 

Receiver and transmitter are used for re-
ceiving consumption data and forwarding 
them to other network nodes of the network. 
The memory stores the consumption data. It 
is protected against temporary power drops 
(e.g. mains power failure or replacement of 
the main battery) by a backup battery. The 
network can be read locally via the M-Bus 
interface. The network nodes WT…16.232 
have an additional RS232 interface for rea-
dout purposes. 

WTT16… nodes are battery-operated, while WTX16… require a mains power supply 
AC 100 V…230 V. 

 
The network node consists of 2 major sections: The base and the housing with the 
electronics. It is thus possible to mount the base prior to commissioning, enabling the 
electrical installer to connect the WTX16 to the mains network. At the time of commis-
sioning, the electronics section is snapped on and the electrical connections are made.  
 

Basic design 

Summary of Contents for WTT16 Series

Page 1: ...nent of the Siemeca system It has been designed for use in buildings to create a radio network for receiving and storing the data transmitted by the consumption meters installed in the building Communication between several network nodes is via radio also so that no wiring is required All meas ured values acquired by the consumption meters are continuously exchanged within the network which means ...

Page 2: ... system must not be ex ceeded The network nodes with gateway and integrated M Bus master WTX16 GSM and WTX16 IP are able to read M Bus meters according to EN1434 3 Technical design The network node consists of the following subassemblies transceiver for Siemeca network memory for 500 meters M Bus Slave RS232 optional backup battery power supply mains supply WTX16 battery WTT16 Receiver and transmi...

Page 3: ...ton for switching the display blue 8 Reset button recessed 9 Display 10 Connector not for the user 11 Firmware memory covered up The wall mounted section of the network nodes WTT16 contains only the main battery The wall mounted section of the network nodes WTX16 and WTX16 232 contains the power pack and possibly an additional RS232 interface GND n c RTS CTS Rx Tx 4 2 7 3 5 6 1 1 Mains connection ...

Page 4: ...ing de vices are received stored and further handled by the network Extended standard mode1 M The receiver is always active to ensure fast communication This mode is automatically activated in the case of mains powered opera tion WTX16 It can also be started manually with the ACT26 service tool Installation mo de2 In installation mode the radio network will be configured automatically Metering dev...

Page 5: ...onal interface s CAUTION connect the mains cable to the power supply unit only 1 2 3 1 Mains connection L and N 2 Preinstalled mains cable no flexible power cable 3 Extra insulation shrink sleeve Connect the AC 230 V power supply line to the power pack of the WTX16 in the following order Remove the upper housing section of the WTX16 from the base For that purpose remove the 2 cable connections pow...

Page 6: ...aintained Staff dealing with the product must be familiar with all potential hazards and mainte nance measures in accordance with the instructions given in this document Non observance of these warning notes can lead to personal injury or damage to property Ensure that the local regulations for radio transmission installations and electrical instal lations are complied with Pursuant to the Verordn...

Page 7: ...similar behavior in other modes too The main battery used by the WTT16 requires careful treatment Do not short circuit or damage the battery Do not expose the battery to excessive heat Return exhausted batteries to the supplier Read the enclosed safety instructions carefully M Bus connection Any network node can be connected to the M Bus temporarily service connector or continuously screw terminal...

Page 8: ...ions in mm WTX16 WTT16 The information provided in this Data Sheet only gives general descriptions and general technical features which in the case of specific applications may not necessarily apply or which may change due to further development of the product Technical features are binding only when expressly agreed upon at the time a contract is concluded 2002 Siemens Building Technologies AG Su...

Reviews: