Termination
module
latch

Latching
side

Z-PLUG Termination Instructions

5

OR

6

Poor lacing

Good lacing

7

> 1 mm
(0.04 in.)

Lace all
four pairs*

Close door with
fingers or with tool

9

8

Preloaded
position

Align termination module latch
(blue/brown side) with plug latch.

Plug Latch

Flush
Cutters
only

Trim flush
0-1 mm
(<0.04 in.)

*Optional:

For large O.D.
cables, pliers
may be helpful
when lacing

Click

Tip for larger OD
cables: Press to
seat before
closing door.

Press

Door

Insert onto
matching shape
with door side up.

2

1

Remove excess
shield to prevent
interference when
attaching boot

foil

braid

OR

2

Summary of Contents for Z-PLUG

Page 1: ...rs in line prior to insertion leading with the brown pair along with either the orange for T568A or green if T568B Not Good OSP F UTP 23 AWG Foil over inner jacket Other cable preparation recommendations and supplemental instructions are available for these and other cable types See back page for additional details End of outer jacket Tip for 22 AWG S FTP Wrap braid on top of foil pairs in directi...

Page 2: ...tion Align termination module latch blue brown side with plug latch Plug Latch Flush Cutters only Trim flush 0 1 mm 0 04 in Optional For large O D cables pliers may be helpful when lacing Click Tip for larger OD cables Press to seat before closing door Press Door Insert onto matching shape with door side up 2 1 Remove excess shield to prevent interference when attaching boot foil braid OR 2 ...

Page 3: ... R2 Use underside of tool handle to defeat termination module latch Unassembling for re termination R1 Remove boot by disengaging latches can use small screwdriver if necessary Boot Removal Removal Tools Flat Screwdriver Z PLUG Tool Probe Pic Optional Press Pull 1 2 Press 1 Remove laced conductors Probe pic use optional Open door using small screwdriver R2 PRESS 2 1 PRESS 1 2 Plug Pin Positions ...

Page 4: ...dans un endroit humide D Ne jamais installer pendant un orage To ensure you have the latest revision to this document please visit Z PLUG Termination Alternate Cable types S FTP Stranded 26 AWG Continue To Step 3 4X Foil 2a 2b 2c 2d 2e 38 mm 1 5 in 13 mm 0 5 in 13 mm 0 5 in Continue To Step 3 U FTP Solid 2a 2b 70 mm 2 75 in 6 35 mm 25 in 1X foil Drain Wire 3X foil 360 2X Note for OSP Category 6A s...

Reviews: