Figure 2

Figure 3

Figure 4

Figure 5

3.

If the hearth and fireplace floor are not at the same

 elevation, leveling legs may be installed on the rear of the unit

(Figure  4)

  for  distances  of  up  to  1".  For  larger  distances

shimming may be used using a non-combustible material. A
Hearth  Base  Support  is  available  from  your  dealer  for
installations where the hearth is below the fireplace opening

(Figure 5)

.

NOTE: THE INSERT WEIGHT IS SUBSTANTIALLY
FRONT HEAVY AND IF NOT FULLY SUPPORTED IT
COULD FALL FORWARD.

4.

Install vent system into existing chimney by using 3" flex
from left side of hearth, passing damper and continuing to
the top of the chimney. If the total vent length is longer than
10 Feet, install Ø4" vent from that point to top of chimney

(Figure 6)

.

5.

Pack fiberglass insulation around the vent pipe and
combustion air duct. Install a flashing cover over
chimney. Secure flashing and seal as required. Install
listed vent cap and secure.

6.

Measure  fireplace  opening  and  adjust  hopper  top  to  the
required  level  allowing  for  installation  clearance.  This  is
accomplished by removing the four #8 screws on the sides

3

Summary of Contents for EasyFire EF4001C

Page 1: ...LETS OF HIGHEST BTU OUTPUT AND LOWEST OF ASH CONTENT ONLY Burning biomass fuels in other forms or poor quality pellet fuel is not permitted and will void your warranty and or could cause a burn back or house fire FOR BEST RESULTS THE WOOD PELLET FUEL SHOULD BE DIAMETER AND APPROXIMATELY 1 Burning other forms of fuel is not permitted and will void all warranties This unit has been approved for use ...

Page 2: ...N OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM INSTALLATION INSTRUCTIONS Check with local building officials for specific code requirements A listed type L Pellet Vent Pipe or Stainless Liner is MANDATORY on all installations WARNING Installation of a Mobile Attachment Home Kit P N 10412 and outside combustion air is mandatory in mobile or modular home ins...

Page 3: ...IF NOT FULLY SUPPORTED IT COULD FALL FORWARD 4 Install vent system into existing chimney by using 3 flex from left side of hearth passing damper and continuing to the top of the chimney If the total vent length is longer than 10 Feet install Ø4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation around the vent pipe and combustion air duct Install a flashing cover over chi...

Page 4: ...he installation a Unplug heater from wall outlet and 12VDC power b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of cou...

Page 5: ... then 12 gauge wire must be used Check with your local electrical professional to make sure you have used the proper gauge wire cable a Unplug heater from wall outlet and 12VDC power b Mount millivolt style remote receiver box to rear of stove using double sided tape b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 d Reconnect AC power and follow instructions with remo...

Page 6: ...placed on a noncombustible floor or ground well away from all fuels pending final disposal This heater when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 2006 Provide adequate clearances around air openings into the combustion chamber and adequateaccessibilityclearance for servicing and proper ...

Page 7: ... the FAN position B In the LOW position the EASYFIRE will be feeding approximately 1 to 1 lbs of pellets per hour and the flame will fluctuate between 1 and 6 in height C In the MEDIUM position the EASYFIRE will be feeding approximately three 3 pounds of pellets per hour and the flame will fluctuate between 3 and 8 of fire D In the HIGH position the EASYFIRE will be feeding approximately 4 lbs per...

Page 8: ...again This will give you another 10 minutes to get the pellets lit The reason for the timer function is so that the heater will automatically shut down if the fire goes out Pellets do not feed in the FAN position B In the LOW position the EASYFIRE will be feeding approximately 1 to 1 lbs of pellets per hour and the flame will fluctuate between 1 and 6 in height C In the MEDIUM position the EASYFIR...

Page 9: ...ding on hopper height Open the top lid and fill the hopper with pellets Figure 9 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your heater We suggest that you try several brands until you find one that gives you a clean effi cient burn Poor quality pellets will burn rich with black soot and ash will accumulate quickly Qualitypellets will burn clean and as...

Page 10: ...NG Risk of electrical shock disconnect all power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE CLEANING Your EASYFIRE Pellet Heater requires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fly ash Some ash will accumulate in the heat exchan...

Page 11: ...nd a soft clean cloth to wipe any marks off all gold surfaces or the heat will cause the marks to remain in the surface permanently Always clean the gold surface when the heater is COOL 7 Door glass replacement Should the door glass become broken it may be replaced by scraping the sealer from around the outer edge of the glass Carefully pry glass from door frame then clean all sealer from frame Ob...

Page 12: ...an and or clean your pipe and heater thoroughly If you feel the Fly ash build up is excessive we suggest that you try another brand In moist climates the pellets and Fly ash can actually absorb moisture from the air and create creosote and a severe clogging problem Keep this in mind when you store and handle your pellets The heater warranty does not cover the quality of the fuels used or the way t...

Page 13: ...BLY 6 120114 CONTROL BOARD V2 1 6A 110080 MAIN FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL V2 12 120120 IGNITOR RELAY 13 120118 PUSH BUTTON SWITCH V2 1 14 110058 HANDLE ASSEMBLY 15 10407 SURROUND ASSEMBLY 63 Laxalt Dr Carson City NV 89706 Phone 1 775 241 2586 Fax 1 ...

Page 14: ...www sierraproductsinc com P N 140706r7 02 21 ...

Reviews: