background image

Figure 12

Figure 13

3.

If you decide to purchase your own 12V back up system
we recommend a sealed gel cell battery. Failure to install
the proper battery could cause physical harm to you and
your property and will also void the heater warranty.

4.

When the battery is properly connected and the heater
plugged in, the following will happen automatically:

a.

The heater will automatically switch to 12V power if
there is a power failure, and switch back when power
is restored.

b.

The battery will be trickle charged as long as the
heater is plugged into 110 AC wall outlet. Do not use
extension cords. The trickle charge will not recharge
a low or dead battery but it will keep a charged
battery at maximum performance.

5.

If you choose to separate the battery from the heater by
lengthening the cables you must make sure that the
cable wire used will carry the current to the heater.  For
example, if the distance is 10 to 20 feet then 12 gauge
wire must be used. Check with your local electrical
professional to make sure you have used the proper
gauge wire/cable.

DC OPERATION - BUILDING A FIRE AND
START-UP

IMPORTANT (Gold  Units  Only):

  Gold  is  a soft  metal  and

therefore a fragile surface. Prior to the first burn it is important
to use Windex™ or comparable product with a soft clean cloth
to wipe any marks off all gold surfaces.
If not cleaned prior to first burn, the heat may cause the marks
to remain in the surface permanently.

Always clean the gold surface when the heater is COOL.

1. Filling the Hopper and Start-Up:
CAUTION:

  Fuel hopper lid must be closed before

operating unit.  Maintain hopper seal in good condition.
  

DO NOT OVERFILL HOPPER!

  The 

EASYFIRE will hold

about 35 lbs. to 50 lbs. of pellets depending on hopper
height.

Open the top lid and fill the hopper with pellets (

Figure 9

).

The quality of pellet fuel varies from brand to brand. This

will affect the efficiency of your heater. We suggest that you
try several brands until you find one that gives you a clean effi-
cient burn. Poor quality pellets will burn rich with black soot
and ash will accumulate quickly.  Quality pellets will burn clean
and ash build up will be minimal.

Make sure hopper lid is fully closed. Open the front door.

Fill the Fire Pot with pellet fuel.

IMPORTANT:

 The Fire Pot must be seated flush and

must sit even in the pot tray. Air leaking around the Fire Pot
will create a poor burn (

Figure 10)

. Light the pellets in Fire

Pot using any approved lighter fluid.

Allow pellets to burn for approximately 1 minute, or until

pellet ignition has been achieved. 

Close door 

and turn the

control knob to the 

"FAN"

 position. Allow fire to burn for

several minutes. When the pellets are well lit, turn the
control knob to 

"LOW"

 for approximately 10 minutes then

turn up to 

"HI"

.  We recommend that you run the heater on

“Medium” or "HI" for about 30 minutes in order to get the
heat exchanger hot before turning it to "LOW".  You will
need to burn the heater for a few hours before deciding
which setting is best for your particular needs.

Note: Caution must be taken when installing burn pot
or operating door not to damage ceramic glass. Do not
attempt to operate heater if glass becomes damaged in
any way!

2. Control Functions:

  Control functions on the Easyfire

are as follows:  OFF, FAN, LOW, MEDIUM, HIGH, CLEAN.
Here is how each function works:

A.

When the Control is set to 

FAN

, a timer is activated

and you will have about ten (10) minutes to get the
pellets lit and reach a minimum temperature.  

Should the pellets not light in the 10 minutes simply turn
the knob to 

OFF

 and begin again.  This will give you

another 10 minutes to get the pellets lit.  The reason for

9

Summary of Contents for EasyFire EF4001C

Page 1: ...LETS OF HIGHEST BTU OUTPUT AND LOWEST OF ASH CONTENT ONLY Burning biomass fuels in other forms or poor quality pellet fuel is not permitted and will void your warranty and or could cause a burn back or house fire FOR BEST RESULTS THE WOOD PELLET FUEL SHOULD BE DIAMETER AND APPROXIMATELY 1 Burning other forms of fuel is not permitted and will void all warranties This unit has been approved for use ...

Page 2: ...N OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM INSTALLATION INSTRUCTIONS Check with local building officials for specific code requirements A listed type L Pellet Vent Pipe or Stainless Liner is MANDATORY on all installations WARNING Installation of a Mobile Attachment Home Kit P N 10412 and outside combustion air is mandatory in mobile or modular home ins...

Page 3: ...IF NOT FULLY SUPPORTED IT COULD FALL FORWARD 4 Install vent system into existing chimney by using 3 flex from left side of hearth passing damper and continuing to the top of the chimney If the total vent length is longer than 10 Feet install Ø4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation around the vent pipe and combustion air duct Install a flashing cover over chi...

Page 4: ...he installation a Unplug heater from wall outlet and 12VDC power b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of cou...

Page 5: ... then 12 gauge wire must be used Check with your local electrical professional to make sure you have used the proper gauge wire cable a Unplug heater from wall outlet and 12VDC power b Mount millivolt style remote receiver box to rear of stove using double sided tape b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 d Reconnect AC power and follow instructions with remo...

Page 6: ...placed on a noncombustible floor or ground well away from all fuels pending final disposal This heater when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 2006 Provide adequate clearances around air openings into the combustion chamber and adequateaccessibilityclearance for servicing and proper ...

Page 7: ... the FAN position B In the LOW position the EASYFIRE will be feeding approximately 1 to 1 lbs of pellets per hour and the flame will fluctuate between 1 and 6 in height C In the MEDIUM position the EASYFIRE will be feeding approximately three 3 pounds of pellets per hour and the flame will fluctuate between 3 and 8 of fire D In the HIGH position the EASYFIRE will be feeding approximately 4 lbs per...

Page 8: ...again This will give you another 10 minutes to get the pellets lit The reason for the timer function is so that the heater will automatically shut down if the fire goes out Pellets do not feed in the FAN position B In the LOW position the EASYFIRE will be feeding approximately 1 to 1 lbs of pellets per hour and the flame will fluctuate between 1 and 6 in height C In the MEDIUM position the EASYFIR...

Page 9: ...ding on hopper height Open the top lid and fill the hopper with pellets Figure 9 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your heater We suggest that you try several brands until you find one that gives you a clean effi cient burn Poor quality pellets will burn rich with black soot and ash will accumulate quickly Qualitypellets will burn clean and as...

Page 10: ...NG Risk of electrical shock disconnect all power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE CLEANING Your EASYFIRE Pellet Heater requires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fly ash Some ash will accumulate in the heat exchan...

Page 11: ...nd a soft clean cloth to wipe any marks off all gold surfaces or the heat will cause the marks to remain in the surface permanently Always clean the gold surface when the heater is COOL 7 Door glass replacement Should the door glass become broken it may be replaced by scraping the sealer from around the outer edge of the glass Carefully pry glass from door frame then clean all sealer from frame Ob...

Page 12: ...an and or clean your pipe and heater thoroughly If you feel the Fly ash build up is excessive we suggest that you try another brand In moist climates the pellets and Fly ash can actually absorb moisture from the air and create creosote and a severe clogging problem Keep this in mind when you store and handle your pellets The heater warranty does not cover the quality of the fuels used or the way t...

Page 13: ...BLY 6 120114 CONTROL BOARD V2 1 6A 110080 MAIN FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL V2 12 120120 IGNITOR RELAY 13 120118 PUSH BUTTON SWITCH V2 1 14 110058 HANDLE ASSEMBLY 15 10407 SURROUND ASSEMBLY 63 Laxalt Dr Carson City NV 89706 Phone 1 775 241 2586 Fax 1 ...

Page 14: ...www sierraproductsinc com P N 140706r7 02 21 ...