2

Figure 1

 -

Overall Dim ensions

Figure 2

OUTSIDE COM BUSTION AIR IS M ANDATORY IN
M OBILE OR M ODULAR HO M E INSTALLATIONS.

CAUTION: DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM .

VENTING AND INSTALLATION
CLEARANCES

CONTACT LOCAL BUILDING OFFICIALS ABOUT RE-
STRICTIONS AND INSTALLATION INSPECTION
REQUIREM ENTS IN YOUR AREA.

A LISTED, 4" M INIM UM  TYPE "L" PELLET VENT PIPE
IS M ANDATORY ON ALL INSTALLATIONS.

DO NO T INSTALL A FLUE DAM PER IN THE EXHAUST
VENTING SYSTEM  OF THIS UNIT, DO NOT CONNECT
THIS UNIT TO  A CHIM NEY FLUE SERVING ANOTHER
APPLIANCE.

Use only listed 4" m inim um  Type "L" pellet vent and
com ponents for installation. The exhaust vent system
m ust be attached to the unit and to each adjoining section.
All joints for connector pipe shall be fastened with at least
three screws. If vented horizontally, joints shall be m ade
gas-tight by sealing with high tem perature silicon or
m aterial specified by vent pipe m anufacturer. Failure to
use listed pellet vent pipe or install it per m anufacturers
instructions will void your warranty.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER

Vent Pipes’ inner and outer diameters may vary. Check
with vent pipe manufacturer for further details. 

W ARNING: Installation of a M obile Hom e Attachm ent Kit
P/N 10412 and outside com bustion air is mandatory in
m obile or modular hom e installations

 although it m ay

also be used in all residential applications.

An outside air inlet M UST be provided for combustion
and ventilation air.

  The air inlet m ust rem ain unrestricted

while unit is in use.  Outside air connection is located in the
rear of the heater (

Figure 2

). Use conduit pipe or m etal flex

pipe and/or fittings to m ake the air intake hook-up.

CAUTION: STRUCTURAL INTEGRITY OF THE M OBILE
HOM E FLOOR, W ALLS AND CEILING/ROO F M UST BE
M AINTAINED.

1.

W hen deciding on the location of your heater and vent
pipe, try to m inim ize the alteration and refram ing of
structural com ponents of the building. 

Vent pipe m ust

be installed so that access is provided for
inspection and cleaning

.

2.

Avoid installing heater in high traffic areas. Keep
children well away from  the heater when in operation.

3.

A 3" clearance to com bustibles must be m aintained

for horizontal and vertical venting. W hen passing
through ceilings or walls, you m ust use a listed wall
thim ble, m aking sure all com bustible m aterials and
insulation products are a m inim um  of 3" away from  the
pellet vent pipe.

4.

A non-com bustible hearth pad must be used if
installed on a carpet, w ood floor or other com busti-
ble material

 (see 

Figure 3

).

5.

W hen installing the exhaust vent into an existing
chim ney, a tee m ust be installed behind the heater
before going up into the chim ney. This is necessary in
order to rem ove fly ash accum ulation.

6.

Exit termination (distance to openings):

a.

3 ft. m inim um  above any forced air inlet located
within 10 ft.

b.

4 ft. m inim um  below and horizontally or 1 ft. m inim um
above any door, window or gravity air inlet into any
building.

PELLET HEATERS REQUIRE A MINIMUM 5' VERTICAL
RISE FOR PROPER O PERATION. ADDITIONAL RISE
OF 2' FOR EVERY 1' HORIZONTAL BEYOND 1 ½'.
MINIMUM DRAFT REQUIRED IS -.01 IN.WC. @
CONNECTION

.

LOW  DRAFT CONDITIONS RESULT IN OVERFEEDING
AND POOR COM BUSTION. 

Summary of Contents for EF-5001UB

Page 1: ...pe L Pellet Vent System NEVER use gasoline gasoline type lantern fuels kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire Keep all such liquids well away from the heater...

Page 2: ...t must remain unrestricted while unit is in use Outside air connection is located in the rear of the heater Figure 2 Use conduit pipe or metal flex pipe and or fittings to make the air intake hook up...

Page 3: ...3 Figure 3 Figure 4 Figure 5 Figure 6 c 2 ft minimum to an adjacent building and 7 ft minimum above grade when located adjacent to public walkways...

Page 4: ...emove factory jump wire and hook up thermostat wires to terminals Figure 7 8 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wi...

Page 5: ...activated and the stove operates based on the EasyFire digital control system requirements If the house AC power should quit the AutoLite system will not be available however with the optional battery...

Page 6: ...e stove will begin to heat up W hen the stove reaches start up operating temperature it will then switch to the control panel setting and begin it s automatic operation cycle Feed Trim Adjustment Unde...

Page 7: ...spring to return against stop Figure 10 11 Once ash box is full box should be placed in a non combustible floor or on the ground well away from all combustible materials pending final disposal If the...

Page 8: ...quires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fly...

Page 9: ...Replace with Pyro Ceramic Glass only Refer to parts list for specifications TROUBLE SHOOTING The following scenarios are provided in order to help you locate a difficulty if the heater performs in a m...

Page 10: ...blem Feed system jammed Solution This condition is caused by fuel contaminated with hard materials such as rocks or metal objects To correct this remove all pellets from hopper Unplug heater from any...

Page 11: ...LA BATTERY 4 202228 BATTERY DRAWER 5 300522 ASH DRAWER 6 300513 FIRE POT 5001 AL 7 120117 AUTOLITE IGNITOR 8 110451 ASH DUMP KNOB 9 110058 HANDLE ASSEMBLY 10 120114 DOOR CATCH 11 300106 AUTOLITE SWITC...