Rev 3 Feb.17
11
4118699
2
2: Installation and Startup
This chapter describes:
•
How to connect, install and start the MG90
•
Front panel LEDs
•
I/O functionality
Note: Field wiring and connections in hazardous locations must be
connected as per the wiring methods requirement for Class 2 circuits
mentioned in the National Electric Code and the Canadian Electric Code.
Note: The MG90 installation must be done by a qualified technician.
Powering the MG90 On
The MG90’s factory default configuration enables it to establish a
WAN connection if an appropriate SIM card is installed, and the APN
is configured correctly.
Note: Additional configuration is always recommended.
To start the MG90:
1.
Apply power to the system:
·
If the MG90 has been installed and wired into a vehicle's
electrical system, turn on the ignition.
·
If the MG90 is not in a vehicle (for example, on a test bench),
use the optional AC power adapter.
The MG90 should fully power up within two minutes. When the
MG90 is turning on, the Power LED flashes green, then turns
solid green, and other LEDs begin to display their regular behav-
ior. For more information on the LED patterns see
2.
If the MG90 does not start automatically, press and release the
Reset button on the front panel.
3.
Test the unit—Connect a test device (for example, a PC) to the
MG90 LAN via:
·
Wi-Fi—An MG90 with factory default settings provides an
unsecured Vehicle Wi-Fi access point (AP) broadcasting its
own Serial Number as the SSID (e.g. ND60510068011018)
·
Ethernet—Ethernet ports 1–4 (factory default configured for
LAN access)
Refer to the AirLink MG90 Software Configuration Guide for
configuration/usage instructions.