AirLink MP70 Hardware User Guide
Rev 4 Nov.16
36
4119008
Power Adapter Pins
4-Pin connector:
•
Power
•
Ground
•
Configurable digital I/O and analog voltage input sensing
•
Configurable ignition sense
Reset
Manual reset button or using ACEmanager
LEDs
See
6 LEDs:
•
Power
•
Network
•
Signal
•
Activity
•
GNSS
•
Wi-Fi
Mechanical Specifications
For mechanical drawings, dimensions, and
weight, see
•
Housing—The MP70 is made of ruggedized powder-coated
aluminum.
•
RoHS2—The MP70 complies with the Restriction of Hazardous
Substances Directive 2011/65/EU (RoHS2). This directive
restricts the use of hazardous materials in the manufacture of
various types of electronic and electrical equipment.
Screw Torque Settings
•
Mount screws
1.1 N-m (10 in-lb)
•
Antennas
Finger tight (5–7in-lb.) is sufficient and the max torque should
not go beyond 1.1 N-m (10 in-lb).
Operating Voltage
Input voltage: 7–36V
By default, the router is configured to enter Standby mode at 9 V. If
you want to operate the router at less than 9 volts, power it on using
at least 9 V, launch ACEmanager, go to Services > Power
Management and adjust the Standby mode settings.
The maximum ripple voltage to guarantee analog input accuracy
must be 100 mVpp.
Table 3-1: Specifications (Continued)