AirPrime WP8548 / WP75xx / WP76xx / WP77xx AT Command Reference
208
Proprietary and Confidential - Contents subject to change
4118047
!GPSXTRATIME
Inject GPS or UTC time into XTRA system
Inject the GPS or UTC time into the XTRA system.
Password required:
Yes (see
for details)
Usage:
•
Execution:
AT!GPSXTRATIME=<YYYY>, <MM>, <DD>, <hh>, <mm>, <ss>,
<utc>, <force>, <uncrtn>
Response:
OK
or
Error code = <err>
OK
Purpose:
Inject the specfied date and time into the XTRA system. If the
command fails, it returns “Error code = <err>”.
•
Query List:
AT!GPSXTRATIME=?
Purpose:
Return supported parameter values.
Parameters:
<YYYY> (Year)
•
4 digits required
<MM> (Month)
•
Valid range: 1–12
<DD> (Day)
•
Valid range: 1–31
<hh> (Hour)
•
Valid range: 0-23
<mm> (Minute)
•
Valid range: 0–59
<ss> (Second)
•
Valid range: 0–59
<utc> (Flag indicating time type)
•
0=GPS time
•
1=UTC time
<force> (Force or allow GPS subsystem to decide to accept the time entered)
•
0=Do not force acceptance
•
1=Force acceptance
<err> (Error code returned if command fails)
•
3=Bad CRC for XTRA data file
•
4=Old XTRA data file
•
7=GPS subsystem busy
•
8=GPS time reference entered is invalid
•
9=Unknown error
Table 8-2: GPS Command Details (Continued)
Command
Description