AirPrime XS1110 AT Command Reference
Rev 3.1 Jul.20
36
41113737
Parameters:
<action> (PVT log mode)
•
0—Disable (Default)
•
1—Enable
•
2—Erase
•
3—Set recording mode
<override_mode> (PVT log override mode)
•
0—Stop recording data (Default)
•
1—Override data from the beginning
•
2—Only override the last record and keep the other data
<cycle> (PVT log recording cycle) (unit: second)
•
Range:1-3600.
•
Default: 15 second
<sector> (Calculate PVT log sentences)
•
Maximum value: 48
<log size> (PVT log size)
•
Unit: byte
<log_data> (The binary data of PVT Log)
Note: Enter the execute disable comment (=0) before reading or executing the erase and write
parameters.
Examples:
•
Enable PVT log:
AT+GNSSPVTL=1<CR><LF>
+GNSSPVTL,1,OK*22<CR><LF>
•
Set override mode to stop recording data and cycle to 5 seconds:
AT+GNSSPVTL=3,0,5<CR><LF>
+GNSSPVTL,3,0,5,OK*25<CR><LF>
•
Get PVT Log data:
+GNSSPVTL,01,90000064DC040080271B00040080007A0A54235C,
41010064A801008047180004000000420C54235C,
370000645C03008027190004000000240E54235C,
B841BF6368050080471A0004000000821054235C,
OK*62<CR><LF>
Table 3
-
2: Other Commands (Detail) (Continued)
Command
Description