Raven iDEN
112
20070914
\APASSTHRU
Note: This mode is not available
through the remote AT telnet
server. You will need to connect
to the Raven with it connected
directly to your computer.
Sets
the
modem
operation
to
pass
through
mode.
This
mode
will
pass
any
characters
received
on
the
port
Ethernet
directly
to
the
internal
hardware
module
and
output
any
characters
from
the
internal
hardware
module
out
the
port
Ethernet.
This
allows
direct
access/configuration
of
the
hardware
module.
Once
this
mode
is
entered,
the
unit
must
be
physically
reset
to
return
to
normal
operation.
This
command
is
not
available
in
AceManager.
Note: It may take up to 30 seconds for the hardware module to
respond after CONNECT is output.
*CSX1=
n
PassThru
Echo
:
Echo
data
to
the
host.
•
n=0
:
Data
will
be
passed
to
the
host.
•
n=1
:
PASSTHRU
mode
will
echo
all
host
received
data
and
will
not
pass
the
data
to
the
modem
while
the
modem
is
not
asserting
DCD.
Note: If the modem is asserting DCD, data will be passed from the
host to the modem as it normally is when *CSX1=0.
*PTINIT=
string
Any
AT
Command
string
to
be
passed
to
the
OEM
module
before
entering
PASSTHRU
mode,
e.g.
AT&S1V1,
etc.
•
string=AT
command(s)
*PTREFRESH=
n
Number
of
minutes
of
inactivity
in
PASSTHRU
mode
to
resend
the
*PTINIT
string
to
the
hardware
module.
•
n=0
:
Disabled
•
n=1
‐
255
minutes
*RESETPERIOD=
n
In
PASSTHRU
mode,
modem
will
be
reset
after
this
period
if
no
data
has
been
sent
or
received.
Value
is
in
hours.
•
n=0
:
Disabled
•
n=1
‐
255
hours