background image

8

Door Adjustm ent

Sierra Products, Inc.
5061 Brooks St., Ste B
Montclair, CA 91763
(909) 399-3355

Should you have a warranty claim on your Sierra-Sierra Stove, notify your nearest  dealer, or
contact Sierra Products, Inc. at the above address.

R77 Replacement Parts List

100045.1

Metallic Black Touch Up #3609

410079

Therm ostat Brass Rod R65/ 77

410080

Therm ostat Knob R65/77

410081

Flue Dam per R65/77

410082

Outer Grate Ring R65

410084

R77 Center Grate

410086

Bi- Metal Therm o Spring R65/77

410088

Door Assem bly R65/77

410089

Door Gasket R65/77

410090

Door Handle Assy. R65/77

410094

Rear Refractory Liner

410095

Side Refractory Liner

421222

Shaker Handle

422232

Outer Grate Support Plate R77

SERVICE TIPS (Continued)

(To be Performed Only by Qualified Installers)

4.

If neither steps 2 or 3 adjusts as desired,

loosen catch (2 bolts0 and position in or out as
required (see figure below )

To check for gasket seal, place a folded sheet of
paper betw een the door and fram e w ith the door

shut. Pull paper to feel friction betw een the gasket
and door fram e.

By following the m anufacturer’s recom m endations your

Sierra Stove will give you years of service.

CONSUM ER PROTECTION W ARRANTY

Your Sierra Stove has a Lim ited Five-Year W arranty. 

Please read it carefully, fill out the short registration form
and return it, within 30 days of purchase, to Sierra

Products, Inc., 5061 Brooks St. Ste. B 
Montclair, CA 91763.

P/N 140819 R77E MANUAL r1

Summary of Contents for Shenandoah R77-E

Page 1: ...fore installation Save these instructions GENERAL INFORMATION Congratulations on your purchase of the Sierra Stove W e are confident that your new stove will provide you with years of safe comfortable and efficient heating This manual describes the installation and operation of the Shenandoah R 77E wood burning heater Please read this entire manual before you install and use your new room heater F...

Page 2: ...es and extends 16 beyond the ash and loading doors and under the chimney connector 2 beyond each side 2 IF APPROVED FLOOR PROTECTION IS NOT USED Use the following calculation to determine if a proposed alternate floor protector meets the requirements listed in the appliance manual a Convert specification to R value i R value is given no conversion is needed ii K factor is given with a required thi...

Page 3: ...e keeping minimum clearances in mind It should have no more than two 90 degree elbows The horizontal connectors are required by NFPA National Fire Protection Association No 211 to have at least inch rise to the linear foot It should be easily accessible for cleaning and should not pass through walls floors or ceiling without being properly insulated for heat The connector pipe should not be instal...

Page 4: ...ion Too little draft can cause smoke to puff from the thermostat damper or from the door To increase draft use a larger flue pipe shorten connector pipe or extend chimney height Too much draft could cause overheating A barometric damper installed in the connector pipe close to the heater can control excessive draft The flue area of the chimney should be a minimum area equivalent to 6 diameter flue...

Page 5: ... place DO NOT IN ANYWAY CAUSE THE UNIT TO OVER FIRE BY OVERRIDING THE THERMOSTAT CONTROL This is an unsafe operation of the unit and could severely damage the unit as well as endanger your home For this reason this type of operation would invalidate the warranty Burning Wood To start a wood fire place crumpled newspaper on the grate and cover it with kindling wood in a criss cross pattern Then pla...

Page 6: ...above 250 degrees Fahrenheit Below 250 degrees Fahrenheit produces black liquid creosote 4 Rather than burn the heater extensively at a low setting during the mild temperatures of 50 degrees and above build a small hot fire for a short period of time Chimney inspection and cleaning The chimney and heater should be inspected for creosote buildup every two weeks during the heating season Creosote is...

Page 7: ...are stores Care should be taken to avoid damaging the flue liner Chimney cleaning service is available in most areas D Firebrick Inspection At least once a year check the condition of the firebrick lining All broken firebricks should be replaced New firebrick can be obtained from your Shenandoah dealer SERVICE TIPS To be Performed Only by Qualified Installers Re calibrating Thermostat Control Note...

Page 8: ...Side Refractory Liner 421222 Shaker Handle 422232 Outer Grate Support Plate R77 SERVICE TIPS Continued To be Performed Only by Qualified Installers 4 If neither steps 2 or 3 adjusts as desired loosen catch 2 bolts0 and position in or out as required see figure below To check for gasket seal place a folded sheet of paper between the door and frame with the door shut Pull paper to feel friction betw...